Etude comparative sur les coefficients de transfert de chaleur côté air de plusieurs types d'évaporateurs utilisés dans les congélateurs et réfrigérateurs domestiques.

Comparison of the air-side heat transfer coefficients of several types of evaporators of household freezer/refrigerators.

Auteurs : LEE T. H., LEE J. S., OH S. Y., et al.

Résumé

The types considered in this study are: spine finned tube type (in-line tube array), continuous flat-plate fin-tube type (staggered tube array), and discrete flat-plate fin-tube type (in-line tube array). The computer programmes were coded using the section-by-section method similar to the tube-by-tube method to calculate the heat transfer coefficients from the experimental results of the heat exchangers. The results indicate that the air-side heat transfer performance of spine finned-tube type (in-line tube array) heat exchangers show the highest value among these three heat exchangers under dry conditions.

Détails

  • Titre original : Comparison of the air-side heat transfer coefficients of several types of evaporators of household freezer/refrigerators.
  • Identifiant de la fiche : 2003-1295
  • Langues : Anglais
  • Source : 2002 Purdue conferences. 2002 compressor engineering & refrigeration and air conditioning conferences at Purdue [CD-ROM].
  • Date d'édition : 16/07/2002
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres communications du même compte rendu (64)
Voir le compte rendu de la conférence