Résumé
This paper has carried out a few experiments on the performance of air cooler to obtain the varied heat transfer coefficient in relevant operational. Based on experimental results, the heat transfer coefficient of the used domestic air cooler with smooth tube is far behind the Roller’s with the smooth tube and internally finned tube. The heat transfer theoretical analysis indicates the domestic air cooler supposes to have a higher efficiency. But the efficiency happens to be lower by the factors of the material selection of finned tube, fluid passage arrangement, production technology, uniform distribution of the air flow and air resistance, and so on.
Documents disponibles
Format PDF
Pages : 6 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance research of the air cooler used in refrigeration device.
- Identifiant de la fiche : 30002443
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Date d'édition : 21/08/2011
Liens
Voir d'autres communications du même compte rendu (569)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Systèmes à compression;
Evaporateurs, condenseurs et autres échangeurs thermiques;
Transfert de chaleur;
Transfert de masse;
Applications domestiques (réfrigérateurs, congélateurs) - Mots-clés : Coefficient de transfert de chaleur; Refroidisseur d'air; Réfrigerateur domestique; Performance; Experimentation; Construction
-
Comparison of the air-side heat transfer coeffi...
- Auteurs : LEE T. H., LEE J. S., OH S. Y., et al.
- Date : 16/07/2002
- Langues : Anglais
- Source : 2002 Purdue conferences. 2002 compressor engineering & refrigeration and air conditioning conferences at Purdue [CD-ROM].
Voir la fiche
-
Comparison and possible improvements of heat tr...
- Auteurs : RIVIS E.
- Date : 12/05/1993
- Langues : Anglais
- Source : Energy Efficiency in Refrigeration and Global Warming Impact.
- Formats : PDF
Voir la fiche
-
Experimental analysis of R134a and R1234ze(E) f...
- Auteurs : RIGHETTI G., ZILIO C., LONGO G. A.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Experimental analysis of no-frost domestic refr...
- Auteurs : OLIET C., RIGOLA J., PÉREZ-SEGARRA C. D., et al.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche
-
Numerical analysis of no-frost domestic refrige...
- Auteurs : OLIET C., PÉREZ-SEGARRA C. D., OLIVA A., et al.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche