Étude des performances d’une pompe à chaleur selon le ratio du mélange des frigorigènes isobutane/propane.

A study on the performance of heat pump by mixing ratio of isobutane/propane mixed refrigerants.

Numéro : No 354

Auteurs : KANG G. H., NA S.-I., KIM M. S.

Résumé

Natural refrigerants have global warming potential (GWP) and ozone depletion potential (ODP), but typical natural refrigerants have low COP, too. On the contrary, hydrocarbon refrigerants have high performance. In this study, using the characteristics of mixed refrigerants that can maintain a constant temperature difference during phase change, performance of the cycle according to the change in mixing ratio of isobutane and propane was calculated and measured. At outdoor temperature of 35°C and indoor temperature 27°C, COP of the cycle was maximized at isobutane ratio is near 0.8. 

Documents disponibles

Format PDF

Pages : 5 p.

Disponible

Gratuit

Détails

  • Titre original : A study on the performance of heat pump by mixing ratio of isobutane/propane mixed refrigerants.
  • Identifiant de la fiche : 30030123
  • Langues : Anglais
  • Sujet : Technologie
  • Source : 13th IEA Heat Pump Conference 2021: Heat Pumps – Mission for the Green World. Conference proceedings [full papers]
  • Date d'édition : 31/08/2021

Liens


Voir d'autres communications du même compte rendu (198)