Document IIF

Étude expérimentale d'évaporateurs à écoulement parallèle utilisés dans le système de conditionnement d'air sur le toit d'un bus.

Experimental study on parallel flow evaporators used in roof top bus air conditionings.

Numéro : pap. n. 216

Auteurs : LIANG Y., CHEN J. P.

Résumé

Parallel flow evaporator with louver fins was designed for roof top bus air conditionings instead of fin-and-tube evaporators in this paper. Experimental study was conducted on parallel flow evaporators, the results showed that the heat transfer under wet condition is not significantly influenced when the inclination angle changes from 0° to 40°, while the air side pressure drop increases a lot. The effect of refrigerant charge on cooling capacity and coefficient of performance was researched to find the optimum charge amount for the bus AC system. The newly designed evaporator has the same heat capacity with the original fin-and-tube evaporator, but 57.6% volume reduction and 38% lighter.

Documents disponibles

Format PDF

Pages : 7 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Experimental study on parallel flow evaporators used in roof top bus air conditionings.
  • Identifiant de la fiche : 30015836
  • Langues : Anglais
  • Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
  • Date d'édition : 16/08/2015
  • DOI : http://dx.doi.org/10.18462/iir.icr.2015.0216

Liens


Voir d'autres communications du même compte rendu (657)
Voir le compte rendu de la conférence