Document IIF
Étude expérimentale des performances de chauffage d’un chauffe-eau à pompe à chaleur au CO2 transcritique dans le cadre d’un fonctionnement coordonné à paramètres multiples.
Experimental study on the heating performance of a transcritical CO2 heat pump water heater under Multi-Parameter coordinated matching operation.
Résumé
In CO2 heat pump (HP) water heaters, achieving optimal synergy among operating parameters is essential for maintaining high system performance under varying heating demands. This study investigates a CO2 HP system equipped with an electronic expansion valve (EEV) and ejector throttling. The comprehensive effects of operating parameters—compressor frequency, EEV opening, inlet water flow rate (IWFR), and temperature—on system performance were quantified through the mean normalization method, along with a comparative analysis of the performance under EEV and ejector throttling modes. The results show that ejector throttling improves the coefficient of performance (COP) by 6.5 %. Within a specific range, reducing the EEV opening improves COP, particularly at lower inlet water temperatures and higher IWFRs, achieving a COP of 3.49 (30 Hz, 60 % EEV, 20 °C, 0.6 m3⸳h−1). Compressor frequency, IWFR, and temperature are identified as the primary factors influencing heat transfer rate. The impact of compressor frequency and inlet water temperature on COP is more significant than that of IWFR and EEV opening. To meet hot water demand and maintain high system performance, the weighted influence of each parameter must be carefully evaluated during adjustments to ensure system stability and optimal performance. This study offers valuable insights for developing multi-parameter control strategies for CO2 HP water heaters.
Documents disponibles
Format PDF
Pages : 212-228
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental study on the heating performance of a transcritical CO2 heat pump water heater under Multi-Parameter coordinated matching operation.
- Identifiant de la fiche : 30033834
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 173
- Date d'édition : 05/2025
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2025.02.019
Liens
Voir d'autres articles du même numéro (17)
Voir la source
Indexation
-
Thèmes :
Techniques des pompes à chaleur;
CO2;
Systèmes à compression - Mots-clés : Chauffe-eau; R744; Choc CO2; Pompe à chaleur; Éjecteur; COP; Experimentation
-
Performance optimization of CO2 heat pump water...
- Auteurs : NAWAZ K., SHEN B., ELATAR A., et al.
- Date : 01/2018
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 85
- Formats : PDF
Voir la fiche
-
Real-time energy-efficient operation of a dedic...
- Auteurs : CUI C., REN J., RAMPAZZO M., SONG Y., YIN X., CAO F.
- Date : 12/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 144
- Formats : PDF
Voir la fiche
-
Difference analysis on optimal high pressure of...
- Auteurs : LIANG X. Y., HE Y. J., CHENG J. H., et al.
- Date : 10/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 106
- Formats : PDF
Voir la fiche
-
Study on annual energy performance of transcrit...
- Auteurs : LIANG X. Y., CHENG J. H., HE Y. J., et al.
- Date : 11/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 107
- Formats : PDF
Voir la fiche
-
Energy and exergy analysis of an air-source hea...
- Auteurs : WANG D., LIU Y., KOU Z., et al.
- Date : 10/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 106
- Formats : PDF
Voir la fiche