Étude expérimentale sur l’influence de la charge de frigorigène sur la performance d’une pompe à chaleur transcritique eau-eau au CO2.
Experimental investigation on the influence of refrigerant charge on the performance of trans-critical CO2 water-water heat pump.
Résumé
For the environmentally aware, natural refrigerant such as CO2 is recommended and pursued by researchers for refrigerators. In this paper, a transcritical CO2 heat pump system was set up to investigate the influence of refrigerant charge on the performance of a small-sized heat pump water heater. The transcritical CO2 heat pump system was composed of a rotary compressor, a tube-in-tube evaporator and gas cooler, an electronic expansion valve (EEV), and an internal heat exchanger (IHX). Based on the experimental results, the effects of refrigerant charge on the key pressures, mass flow rate, power consumption, discharge temperature, superheat, heating capacity and coefficient of performance (COP) were analyzed with different EEV openings. The pressure in the evaporator and gascooler increased with the rise of refrigerant charge. The mass flow rate increased with the refrigerant charge range from 0.6kg to 2.2kg. The experimental results showed that the COP of the system was strongly related to CO2 mass charge and had a maximum value at a specific CO2 mass charge. Undercharged CO2 systems could result in a fast decrease of the heating capacity and COP. The COP reduced more significantly at undercharged conditions than at overcharged conditions as the refrigerant charge further deviated from optimal charge. As EEV opening increased from 40% to 60%, the optimal COP decreased. And with the increase of EEV opening, the corresponding charge amount of optimal COP reduced.
Documents disponibles
Format PDF
Pages : 8
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental investigation on the influence of refrigerant charge on the performance of trans-critical CO2 water-water heat pump.
- Identifiant de la fiche : 30018992
- Langues : Anglais
- Source : 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 11/07/2016
Liens
Voir d'autres communications du même compte rendu (274)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Pompes à chaleur à usage domestique;
CO2 - Mots-clés : Chauffe-eau; R744; Pompe à chaleur; Performance; Charge en frigorigène; Eau-eau
-
Approaching optimal high pressure by charge man...
- Auteurs : HE Y. J., LIANG X. Y., CHENG J. H., SHAO L. L., ZHANG C. L.
- Date : 31/08/2021
- Langues : Anglais
- Source : 13th IEA Heat Pump Conference 2021: Heat Pumps – Mission for the Green World. Conference proceedings [full papers]
- Formats : PDF
Voir la fiche
-
Energy recovering using greywater as cold body ...
- Auteurs : ILLÁN GÓMEZ F., GARCÍA-CASCALES J. R., LÓPEZ BELCHÍ A.
- Date : 18/06/2018
- Langues : Anglais
- Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Formats : PDF
Voir la fiche
-
Performance evaluation of CO2 HPWH s...
- Auteurs : NAWAZ K., SHEN B., ELATAR A., BAXTER D. van, ABDELAZIZ O.
- Date : 07/12/2020
- Langues : Anglais
- Source : 14th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2020). Proceedings. Kyoto, Japon, December 7-9th 2020.
- Formats : PDF
Voir la fiche
-
Modeling and simulation of air-source CO2<...
- Auteurs : GAO Z., RICE K., NAWAZ K.
- Date : 2022
- Langues : Anglais
- Source : 2022 Purdue Conferences. 19th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Experimental investigation of the extreme seeki...
- Auteurs : CUI C., ZONG S., SONG Y., YIN X., CAO F.
- Date : 01/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 133
- Formats : PDF
Voir la fiche