Document IIF

Étude expérimentale sur un éjecteur utilisé dans un système à pompe à chaleur transcritique au CO2.

Experimental study on an ejector used in transcritical CO2 heat pump system.

Numéro : pap. n. 164

Auteurs : LU Y. J., CHEN Q., TONG Y., et al.

Résumé

An experimental transcritical CO2 heat pump water heater system was designed, and the measurement and control system for testing was developed. The performance of transcritical CO2 heat pump systems with (TRCS-EJEC) and without (TRCS) ejector was analyzed by changing flow rate of cooling water or adjusting the throttle valve. The flow rate, entrainment ratio, compression ratio and efficiency of ejector were investigated. The experimental results showed that the heating coefficient of TRCS-EJEC was improved by 7.3% to 13.9% compared with that of TRCS when heated water temperature ranged from 63°C to 55°C. Development of high efficient ejector was a critical factor on optimizing transcritical CO2 heat pump system.

Documents disponibles

Format PDF

Pages : 6 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Experimental study on an ejector used in transcritical CO2 heat pump system.
  • Identifiant de la fiche : 30004289
  • Langues : Anglais
  • Source : 10th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2012). Proceedings. Delft, The Netherlands, June 25-27, 2012.
  • Date d'édition : 25/06/2012

Liens


Voir d'autres communications du même compte rendu (142)
Voir le compte rendu de la conférence