Recommandé par l'IIF / Document IIF
Étude numérique du rapport de vitesse des rideaux d’air dans un meuble frigorifique ouvert équipé d’un double rideau d’air.
Numerical investigation of air curtain velocity ratio in an open refrigerated display cabinet with dual air curtain.
Numéro : 853
Auteurs : CHENG P. S., HSIEH C. H., YU P.
Résumé
The protective effect of air curtains in open refrigerated display cabinets (ORDCs) was investigated by two simulation models. In model A, the velocity of the 5 oC inner air curtain was maintained at 2 m/s and the 8 oC outer air curtain varied from 1 to 3.33 m/s, leading to the velocity ratio ranging from 0.67 to 4. The simulation results showed that the dual air curtain performed best with a velocity ratio of 1.33, resulting in a TEF of 0.21 and a cooling load of 0.48 kW. The ORDC performed worse with outer air curtain velocity that was either too fast or too slow. Model B fixed the total air mass flow rate of the dual air curtain at 67% inner and 33% outer. Compared with a velocity ratio of 4, TEF and cooling load with a velocity ratio of 0.6 increased by 33% and 26%, respectively. Both simulation models showed that a slower velocity for the outer air curtain was more effective in preventing hot ambient air infiltration.
Documents disponibles
Format PDF
Pages : 10
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Numerical investigation of air curtain velocity ratio in an open refrigerated display cabinet with dual air curtain.
- Identifiant de la fiche : 30031320
- Langues : Anglais
- Sujet : Technologie
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Date d'édition : 21/08/2023
- DOI : http://dx.doi.org/10.18462/iir.icr.2023.0853
Liens
Voir d'autres communications du même compte rendu (491)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Supermarchés, meubles de vente
- Mots-clés : Supermarché; Meuble de vente; Modélisation; Simulation; Experimentation; Rideau d'air; Vitesse (fluides)
-
Jet entrainment rate in air curtain of open ref...
- Auteurs : NAVAZ H. K., HENDERSON B. S., FARAMARZI R., et al.
- Date : 03/2005
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 28 - n. 2
- Formats : PDF
Voir la fiche
-
Experimental investigation of plane wall jet: a...
- Auteurs : KAFFEL A., MOUREH J., HARION J-L., et al.
- Date : 23/06/2014
- Langues : Anglais
- Source : 3rd IIR International Conference on Sustainability and the Cold Chain. Proceedings: London, UK, June 23-25, 2014
- Formats : PDF
Voir la fiche
-
Investigation of energy-efficient supermarket d...
- Auteurs : WALKER D. H., FARAMARZI R. T., BAXTER V. D.
- Date : 17/08/2003
- Langues : Anglais
- Source : 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Formats : PDF
Voir la fiche
-
The design considerations of single-band air cu...
- Auteurs : CHEN Y., YUAN X.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Recherche et développement de simulations numér...
- Auteurs : YU K., DING G., CHEN T.
- Date : 04/2011
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 32 - n. 138
- Formats : PDF
Voir la fiche