Étude théorique sur un cycle frigorifique à compression de vapeur modifié avec sous-refroidissement utilisant un mélange d'hydrocarbures R290/R600a.

Theoretical study on a modified subcooling vapor-compression refrigeration cycle using hydrocarbon mixture R290/R600a.

Numéro : pap. 2720

Auteurs : CHEN Q., YU J., YAN G., et al.

Résumé

In this study, a modified subcooling vapor-compression refrigeration cycle (MSVRC) using refrigerant mixture R290/R600a was proposed for applications in refrigerator-freezers. In the MSVRC, a phase separator is utilized to split the refrigerant mixture and obtain refrigerants at two different mass fractions after partial condensation in the condenser. Moreover, an internal heat exchanger is introduced to enhance the overall system performance. Energetic and exergetic analysis methods were used to theoretically evaluate the system operating performance of MSVRC and compared with the conventional vapor-compression refrigeration cycle (CVRC). The simulation results show that the MSVRC outperforms CVRC in terms of coefficient of performance (COP) and exergy efficiency. Under the given operating condition, the COP and exergy efficiency of the MSVRC can be improved up to 5.27% and 11.4%, respectively, as compared to those of CVRC. The system performance characteristics of the proposed cycle demonstrate its potential advantages for application in domestic refrigerator-freezers.

Documents disponibles

Format PDF

Pages : 9

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Theoretical study on a modified subcooling vapor-compression refrigeration cycle using hydrocarbon mixture R290/R600a.
  • Identifiant de la fiche : 30024723
  • Langues : Anglais
  • Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
  • Date d'édition : 09/07/2018

Liens


Voir d'autres communications du même compte rendu (252)
Voir le compte rendu de la conférence