Évaluation comparative des performances de refroidissement naturel d’économiseurs côté eau et côté air pour centres de données dans diverses régions.
Comparative free cooling performance evaluation of water-side and air-side economizers for data centers in various regions.
Résumé
Data centers are growing rapidly, and their power demand is increasing significantly owing to their crucial role in data processing and storage. Recently, the adoption of free cooling methods utilizing economizers has emerged as a strategy to mitigate power consumption for data centers. However, limited research has been conducted on achieving optimal energy efficiency and reducing power consumption for data center operations. Furthermore, owing to the weather-dependent nature of free cooling methods, a regional analysis is essential. The objective of this study is to compare and optimize the free cooling methods utilizing economizers across different regions. TRNSYS was used to model data center systems. Two types of economizers, namely water-side economizer (WSE) and air-side economizer (ASE) systems, were modeled with three weather datasets in Cairo, Seoul, and Toronto. The ASE outperformed the WSE owing to its wider operating temperature range and utilization. In Seoul, when the ASE was applied, the annual PUE decreased from 1.275 to 1.209. Notably, the economizer performance was better in Toronto than in Cairo. When the ASE was applied, the annual power usage effectiveness (PUE) decreased by 0.033, 0.066, and 0.078 in Cairo, Seoul, and Toronto, respectively. This phenomenon was particularly noticeable in regions with cooler climates, where economizers showed enhanced efficiency.
Documents disponibles
Format PDF
Pages : 7 p.
Disponible
Gratuit
Détails
- Titre original : Comparative free cooling performance evaluation of water-side and air-side economizers for data centers in various regions.
- Identifiant de la fiche : 30032911
- Langues : Anglais
- Sujet : Technologie
- Source : 2024 Purdue Conferences. 8th International High Performance Buildings Conference at Purdue.
- Date d'édition : 15/07/2024
Liens
Voir d'autres communications du même compte rendu (63)
Voir le compte rendu de la conférence
-
Energy evaluations between air-cooled vs. water...
- Auteurs : MEDHAT FAHIM A. A., KHALIL E. E.
- Date : 10/06/2007
- Langues : Anglais
- Source : Clima 2007. WellBeing Indoors. Proceedings of the 9th REHVA World Congress [CD-ROM + Abstract book].
Voir la fiche
-
Première de couverture de la note d'information, avec des images de centre de données.
Technologies de refroidissement pour des centre...
- Auteurs : SHAO S., ZHANG P., LI X.
- Date : 01/2025
- Langues : Anglais, Français
- Formats : PDF
Voir la fiche
-
Solar cooling for southern climates, double eff...
- Auteurs : PIETRUSCHKA D., JAKOB U., EICKER U.
- Date : 09/2010
- Langues : Anglais
Voir la fiche
-
La problématique des économies d'énergie dans l...
- Auteurs : BUFFARD V., LAFRANCE G.
- Date : 1991
- Langues : Français
- Source : Rev. Energ. - n. 434
Voir la fiche
-
The impact of air renewal with heat-recovery te...
- Auteurs : CASTILLO SANTIAGO Y., BUSANELLO D., SANTOS A. F., VENTURINI O. J., SPHAIER L. A.
- Date : 08/2024
- Langues : Anglais
- Source : Energies - vol. 17 - n. 16
- Formats : PDF
Voir la fiche