Document IIF
Evaluation de la performance et conception optimale de systèmes frigorifiques pour supermarchés à l'aide du modèle "SuperSim". I. Description et validation du modèle.
Performance evaluation and optimal design of supermarket refrigeration systems with supermarket model "SuperSim". I. Model description and validation.
Auteurs : GE Y. T., TASSOU S. A.
Type d'article : Article, Article de la RIF
Résumé
Conventional supermarket refrigeration systems are responsible for considerable CO2 emissions due to high energy consumption and large quantities of refrigerant leakage. In the effort to conserve energy and reduce environmental impacts, an efficient design tool for the analysis, evaluation and comparison of the performance of alternative system designs and controls is required. This paper provides a description of the modelling procedure employed in the supermarket simulation model 'SuperSim' for the simulation of the performance of centralised vapour compression refrigeration systems and their interaction with the building envelope and HVAC systems. The model which has been validated against data from a supermarket has been used for the comparison of R404A and CO2 refrigeration systems and the optimisation of the performance of transcritical CO2 systems. These results are presented in Part II of the paper.
Documents disponibles
Format PDF
Pages : pp. 527-539
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance evaluation and optimal design of supermarket refrigeration systems with supermarket model "SuperSim". I. Model description and validation.
- Identifiant de la fiche : 2010-1934
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 2
- Date d'édition : 03/2011
Liens
Voir d'autres articles du même numéro (18)
Voir la source
Indexation
-
Thèmes :
Systèmes à compression;
HFC;
CO2;
Supermarchés, meubles de vente - Mots-clés : Système frigorifique; Consommation d'énergie; R404A; Supermarché; Modélisation; Frigorigène; CO2
-
Supermercati CO2 footprint.
- Auteurs : VILLA F.
- Date : 11/2010
- Langues : Italien
- Source : CDA (Condizionamento dell'Aria Riscaldamento Refrigerazione) - n. 10-11
Voir la fiche
-
Performance evaluation and optimal design of su...
- Auteurs : GE Y. T., TASSOU S. A.
- Date : 03/2011
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 2
- Formats : PDF
Voir la fiche
-
Impacto medioambiental de varios sistemas alter...
- Auteurs : KAUFFELD M., HARNISCH M. J., RHIEMEIER J. M.
- Date : 12/2009
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 37 - n. 420
- Formats : PDF
Voir la fiche
-
Supermarket refrigeration system: with complete...
- Auteurs : MINEA V.
- Date : 09/2007
- Langues : Anglais
- Source : ASHRAE Journal - vol. 49 - n. 9
Voir la fiche
-
Case study R744: a transcritical system with he...
- Auteurs : COLOMBO I., JOHAL P., JORDAN L., et al.
- Date : 11/2010
- Langues : Anglais
- Source : RACA Journal - vol. 26 - n. 9
- Formats : PDF
Voir la fiche