Évaluation du choix du frigorigène pour un système à éjection fonctionnant à basse température.
Assesment of refrigerant selection for ejection system driven by low-grade heat.
Numéro : pap. 2667
Auteurs : SMIERCIEW K., BUTRYMOWICZ D., GAGAN J.
Résumé
Ejection refrigeration cycles are driven by thermal energy. This kind of energy use as the motive energy for ejection cycles makes this cycle comparable with absorption system. In absorption system the temperature of the heat source tg in most cases exceeds 100 C. With decreasing of the generator (motive) temperature the efficiency of absorption system also decreases due to vanishing of the difference of strong and weak solutions concentrations. Therefore temperature tg < 80 C can be considered as the minimum value at which the absorption system can still operate. In contrast, for ejection systems for most of working fluids temperature of the motive fluid at the level of 100 C is not required. Also, there is no physical limitation for operation of the ejection system at lower temperatures. Therefore the operation of the ejection cycle below tg < 80 C can be considered as very attractive and in this range of the motive temperatures the ejection cycles becomes truly competitive in comparison with the absorption refrigeration systems. The paper deals with numerical analysis of operation of the ejection systems driven by low grade heat. The aim of the paper is comparison of the operating parameters of the system for natural refrigerant isobutane with other popular in air-conditioning systems refrigerant R134a and one of the most promising fluid from HFO group HFO1234. Three types of HFO1234 has been investigated, such as 1234yf, 1234ze(E) and 1234ze(Z). Analysis shows the promising feature of the HFO1234 applied in ejection system. i.e. geometric similarity of ejectors designed for isobutane and HFO1234. This proves that HFO1234 can be substitution of isobutane due to its flammable and explosive conditions.
Documents disponibles
Format PDF
Pages : 8
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Assesment of refrigerant selection for ejection system driven by low-grade heat.
- Identifiant de la fiche : 30018826
- Langues : Anglais
- Source : 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 11/07/2016
Liens
Voir d'autres communications du même compte rendu (274)
Voir le compte rendu de la conférence
Indexation
-
Thermodynamic analysis of performance of liquid...
- Auteurs : PAWLUCZUK A., BUTRYMOWICZ D., SMIERCIEW K., et al.
- Date : 06/09/2017
- Langues : Anglais
- Source : Compressors 2017: 9th International Conference on Compressors and Coolants.
- Formats : PDF
Voir la fiche
-
Thermodynamic comparison of ejector cooling cyc...
- Auteurs : EXPÓSITO CARRILLO J. A., SÁNCHEZ DE LA FLOR F. J., SALMERÓN LISSEN J. M.
- Date : 02/2017
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 74
- Formats : PDF
Voir la fiche
-
Nowe czynniki chlodnicze i zmiany w instalacjac...
- Auteurs : ANDRZEJCZYK R., MUSZYNSKI T., JAKUBOWSKA B.
- Date : 02/2016
- Langues : Polonais
- Source : Przemysl Spozywczy - vol. 70. n. 2 - vol. 70. n. 2
Voir la fiche
-
Numerical analysis for heat driven ejector refr...
- Auteurs : YOSHIDA T., MATSUBARA T., AJIMA M., IWASAKI M., ELBEL S.
- Date : 05/2021
- Langues : Anglais
- Source : 2021 Purdue Conferences. 18th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Assessment of refrigerant selection for ejectio...
- Auteurs : SMIERCIEW K., KEDZIERSKI M. A., BUTRYMOWICZ D., et al.
- Date : 06/09/2017
- Langues : Anglais
- Source : Compressors 2017: 9th International Conference on Compressors and Coolants.
- Formats : PDF
Voir la fiche