Document IIF

Évaluation expérimentale de la différence de performance entre le R245fa et le R1224yd(Z) comme fluide actif d'un cycle frigorifique à éjecteur.

Experimental assessment on the performance difference between R245fa and R1224yd(Z) as the working fluid of an ejector refrigeration cycle.

Numéro : 0321

Auteurs : ITO T., KUNIYOSHI N., KOJIMA M., TERASHIMA K., SATO H.

Résumé

In order not to consume fossil fuels, electricity demands have rapidly increased to achieve net zero CO2 emissions in 2050. An ejector refrigeration cycle is a heat-driven cooling system that can use waste heat and solar heat with small electric power, so it has the possibility to achieve an electric energy-saving cooling system. The experiments using a low-pressure refrigerant, R245fa, or its alternative refrigerant, R1224yd(Z) were conducted. The COP, the ratio of the cooling capacity to the electricity consumption of the working fluid feed pump, reaches higher than 50 in the case of R1224yd(Z) at the generating and evaporating temperatures of 56 °C and 15 °C. The COP of the total system may be considered to be higher than that of ordinary vaporpressure refrigeration cycles having the COP being around 7 in Japan. In addition, the experimental performance of our testing apparatus using R1224yd(Z) is superior to that using R245fa.

Documents disponibles

Format PDF

Pages : 8 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Experimental assessment on the performance difference between R245fa and R1224yd(Z) as the working fluid of an ejector refrigeration cycle.
  • Identifiant de la fiche : 30031753
  • Langues : Anglais
  • Sujet : Technologie
  • Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
  • Date d'édition : 21/08/2023
  • DOI : http://dx.doi.org/10.18462/iir.icr.2023.0321

Liens


Voir d'autres communications du même compte rendu (492)
Voir le compte rendu de la conférence