Résumé
Driven by the Kigali Amendment and Carbon Neutrality objectives, R404A will be gradually phased out, while it’s now being widely employed in commercial refrigeration equipment. R454C and R290, due to their low GWP and environmental friendliness, have become the most promising alternative refrigerants for commercial refrigeration. To compare the performance of these three different refrigerants in light commercial refrigeration equipment, different commercial refrigerators and display cabinets are tested in our environmental test laboratory.
Critical parameters are compared including refrigerant charge amount, energy consumption, material costs, and carbon emissions of R404A, R454C, and R290 systems. The results indicated that compared with the R404A system, the 24-hour energy consumption of the R454C system can be reduced by about 5 %, and the total carbon emissions can be reduced by about 15 %. As for R290, the system charge is significantly reduced. The charge amounts for commercial refrigerators and display cabinets are only 20.6 % to 34.2 % and 16.4 % to 23.6 % of that of R404A, respectively, leading to a substantial reduction in refrigerant charging costs. Furthermore, the 24-hour energy consumption can be reduced by 16.7 % to 35 % and 11.9 % to 15.7 % respectively. Furthermore, commercial refrigerators demonstrate superior carbon reduction performance, achieving a reduction in carbon emissions ranging from 25.3 % to 43.7 %.
Documents disponibles
Format PDF
Pages : 13 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental investigation on the performance of R290 and R454C as alternative refrigerants in commercial refrigerators and display cabinets.
- Identifiant de la fiche : 30034772
- Langues : Anglais
- Sujet : Technologie
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 185
- Date d'édition : 05/2026
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2026.02.012
Liens
Voir d'autres articles du même numéro (27)
Voir la source
Indexation
-
Thèmes :
Hydrocarbures;
Supermarchés, meubles de vente - Mots-clés : Meuble de vente; R290; R454C; Experimentation; Application commerciale
-
Performance analysis of linear compressor using...
- Auteurs : ZOU H., LI X., TANG M., et al.
- Date : 01/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 109
- Formats : PDF
Voir la fiche
-
Enjeux environnementaux des installations frigo...
- Auteurs : RIVOALLON R.
- Date : 09/2013
- Langues : Français
- Source : Revue générale du Froid & du Conditionnement d'air - vol. 103 - n. 1136
Voir la fiche
-
Badania mebli chlodniczych.
- Auteurs : STEINDEL M., BEDNARCZYK L.
- Date : 11/2006
- Langues : Polonais
- Source : Chlodnictwo - vol. 41 - n. 11
Voir la fiche
-
Procès-verbal de la réunion de la Commission de...
- Date : 01/02/1999
- Langues : Français
- Source : IEC/UNM 46 - UNM 46-226; 28 p.; 4 append.
Voir la fiche
-
Propane as R22-replacement in commercial applia...
- Auteurs : JÜRGENSEN H.
- Date : 13/11/2008
- Langues : Anglais
- Source : Danfoss Compress. - 4 p.; fig.; tabl.
Voir la fiche