Document IIF
Frigorigènes alternatifs de substitution immédiate à faible PRP pour les réfrigérateurs de transport à basse température avec systèmes frigorifiques eutectiques.
Low GWP drop-in alternative refrigerants for low-temperature transport refrigerators with eutectic refrigerating systems.
Numéro : 1121
Auteurs : VAITKUS L., BALCIUS A.
Résumé
The EU Regulation No 517/2014 implemented prohibitions for placing on the market of high GWP R507A and R404A refrigerants. These refrigerants are disappearing from the market, which becomes a serious problem for the refrigerating applications, not directly covered by the prohibitions. For example, these refrigerants were dominant in low-temperature transport refrigerators with eutectic refrigerating systems. For such systems a low-GWP drop-in alternative should be proposed. The eutectic refrigerating system operates at specific conditions with the main limiting factors being low evaporation pressure and high discharge temperature. The applicability of the alternative refrigerants in the eutectic systems is analysed in this article. Test results with the refrigerants R448A, R442A and R452A are provided, with the R452A found to be acceptable as a drop-in replacement. At 38℃ ambient temperature the increase in temperature pull-down time was about 10%, and increase in power consumption was below 4%, when compared to R507A.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Low GWP drop-in alternative refrigerants for low-temperature transport refrigerators with eutectic refrigerating systems.
- Identifiant de la fiche : 30029479
- Langues : Anglais
- Sujet : Alternatives aux HFC
- Source : 7th IIR International Conference on Sustainability and the Cold Chain (Online). Proceedings: April 11-13 2022
- Date d'édition : 11/04/2022
- DOI : http://dx.doi.org/10.18462/iir.iccc2022.1121
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres communications du même compte rendu (49)
Voir le compte rendu de la conférence
Indexation
-
Very low GWP refrigerant R-516a for R-134a repl...
- Auteurs : KIM S., CROSBY K., RODOWSKI D.
- Date : 05/2021
- Langues : Anglais
- Source : 2021 Purdue Conferences. 18th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Field measurements and analysis of supermarket ...
- Auteurs : KHMELNIUK M., KONSTANTINOV I., WOZNIY W.
- Date : 13/01/2021
- Langues : Anglais
- Source : 10th IIR Conference on Compressors and Refrigerants.
- Formats : PDF
Voir la fiche
-
Examining low global warming potential hydroflu...
- Auteurs : SPLETZER S., MEDINA J., HUGHES J.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Evaluación energética del refrigerante R468A co...
- Auteurs : CABELLO LÓPEZ R., GARCIA-VACAS D. S., NEBOT-ANDRÉS L., CALLEJA-ANTA D., LLOPIS DOMÉNECH R.
- Date : 11/11/2020
- Langues : Espagnol
- Source : X Congreso Ibérico y VIII Congreso Iberoamericano de Ciencias y Técnicas del Frío, CYTEF 2020.
- Formats : PDF
Voir la fiche
-
Annual performance evaluation of a refrigerated...
- Auteurs : KITAMURA K., BIZEN K., SUZUKI T., MIYAOKA Y., JEONG J., SAITO K., WATANABE T., IWASAKI T., TAKIGUCHI K.
- Date : 06/2021
- Langues : Anglais
- Source : 2nd IIR Conference on HFO Refrigerants and Low GWP Blends
- Formats : PDF
Voir la fiche