Document IIF
Froid durable dans les supermarchés avec des frigorigènes HFO.
Sustainable supermarket refrigeration with HFO refrigerant.
Numéro : 0017
Auteurs : PUROHIT N., GAO K., BIRBARAH P., SETHI A., HULSE R.
Résumé
The outdoor heat exchanger of the heat pump type pure electric bus is easy to frost in winter, wich leads to the degradation of the air conditioning system performance. In view of this situation, a new generation of refrigerant R1234yf was used to build a heat pump type air conditionning system test-bed for pure electric buses. The superheat of the main valve is set to 5K, and the superheat of the gulp valve is set to 8K, 10K, 12K, respectively. By the experiment of frosting characteristics of evaporation temperature, heat capacity, COP and frosting time under frosting conditions were studied. The experimental results show that the higher the superheat of the gulp valve, the lower the evaporation temperature; when the superheat degree of the gulp valve increases, the heating capacity increases, but the COP of the system decreases.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Sustainable supermarket refrigeration with HFO refrigerant.
- Identifiant de la fiche : 30031026
- Langues : Anglais
- Sujet : Technologie, Alternatives aux HFC
- Source : 3rd IIR conference on HFO Refrigerants and low GWP Blends. Shanghai, China.
- Date d'édition : 05/04/2023
- DOI : http://dx.doi.org/10.18462/iir.HFO2023.0017
Liens
Voir d'autres communications du même compte rendu (28)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
HFO et HCFO;
Supermarchés, meubles de vente;
Systèmes à éjection, cycle à air, cycle Stirling, autres cycles;
Hydrocarbures;
CO2 - Mots-clés : R404A; R448a; Faible GWP; Supermarché; HFO; Système en cascade; Modélisation; COP; Performance; LCCP; Frigorigène naturel; Émission de CO2; R744; R290; Propane
-
Influence of commercial refrigeration system de...
- Auteurs : PETERSEN M., POTTKER G., FRICKE B. A.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
A comparative study on the environmental impact...
- Auteurs : BESHR M., AUTE V., SHARMA V., et al.
- Date : 08/2015
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 56
- Formats : PDF
Voir la fiche
-
Supermarket refrigeration system charge reducti...
- Auteurs : SHARMA V., FRICKE B., BANSAL P.
- Date : 02/08/2014
- Langues : Anglais
- Source : 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF
Voir la fiche
-
Analysis and selection on low GWP refrigerants ...
- Auteurs : YAN H., WANG R., HU B., EIKEVIK T. M.
- Date : 13/06/2022
- Langues : Anglais
- Source : 15th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2022). Proceedings. Trondheim, Norway, June 13-15th 2022.
- Formats : PDF
Voir la fiche
-
Performance, cost and emissions comparison of r...
- Auteurs : ROBERTS N. A., SAAB S., BAILEY J., COOK N.
- Date : 26/08/2020
- Langues : Anglais
- Source : 6th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Nantes, France, August 26-28 2020
- Formats : PDF
Voir la fiche