Illustration de la relation entre le coefficient de performance et le coefficient de performance du système grâce à un système frigorifique de supermarché au R404.
Illustrating the relationship between the coefficient of performance and the coefficient of system performance by means of an R404 supermarket refrigeration system.
Auteurs : BRAUN M. R., WALTON P., BECK S. B. M.
Type d'article : Article, Article de la RIF
Résumé
Because the coefficient of performance (COP) is primarily concerned with the core refrigeration system, using it for optimisation purposes may lead to higher than necessary energy consumption. This hypothesis was studied with a simple equation relating this coefficient to the coefficient of system performance (COSP), and with a software model based on an R404A refrigeration system installed in a supermarket in north east England. In both approaches the condenser fan power usage was excluded from the COP but included in the COSP. The results showed that, especially for part load conditions, optimising the core refrigeration system for minimum power consumption led to an appreciably higher overall energy consumption with the implication that the condenser fan and compressor controls should be developed together. When using this holistic approach it was found that energy savings of 4.5% could have been achieved based on six months' data from the installed system.
Documents disponibles
Format PDF
Pages : 225-234
Disponible
Gratuit
Détails
- Titre original : Illustrating the relationship between the coefficient of performance and the coefficient of system performance by means of an R404 supermarket refrigeration system.
- Identifiant de la fiche : 30018697
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 70
- Date d'édition : 10/2016
Liens
Voir d'autres articles du même numéro (25)
Voir la source
-
Comparing COP optimization with maximizing the ...
- Auteurs : BRAUN M. R., BECK S. B. M., ALTAN H.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Mezclas HFC/HFO para sustituir al R404A en refr...
- Auteurs : MOTA BABILONI A., BARRAGÁN-CERVERA A., NAVARRO-ESBRÍ J., et al.
- Date : 03/05/2016
- Langues : Espagnol
- Source : CYTEF 2016. VIII Congreso Ibérico y VI Congreso Iberoamericano de las Ciencias y Técnicas del Frío, Coimbra-Portugal, 3-6 mayo, 2016.
- Formats : PDF
Voir la fiche
-
New type of energy efficient heat exchanger for...
- Auteurs : HAGLUND STIGNOR C., TILJANDER P., LINDBERG U., et al.
- Date : 06/04/2018
- Langues : Anglais
- Source : 5th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Beijing, Chine, 6-8 avril 2018
- Formats : PDF
Voir la fiche
-
R-449A configurations for energy efficiency imp...
- Auteurs : MOTA BABILONI A., GIMÉNEZ-PRADES P., FERNANDEZ MORENO A., MAKHNATCH P., NAVARRO-ESBRÍ J.
- Date : 01/09/2021
- Langues : Anglais
- Source : 6th IIR Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Formats : PDF
Voir la fiche
-
Theoretical evaluation of integrated systems fo...
- Auteurs : CECCHINATO L., CORRADI M., FORNASIERI E., et al.
- Date : 29/03/2010
- Langues : Anglais
- Source : 1st IIR International Conference on Sustainability and the Cold Chain
- Formats : PDF
Voir la fiche