IIR document
Illustrating the relationship between the coefficient of performance and the coefficient of system performance by means of an R404 supermarket refrigeration system.
Author(s) : BRAUN M. R., WALTON P., BECK S. B. M.
Type of article: Article, IJR article
Summary
Because the coefficient of performance (COP) is primarily concerned with the core refrigeration system, using it for optimisation purposes may lead to higher than necessary energy consumption. This hypothesis was studied with a simple equation relating this coefficient to the coefficient of system performance (COSP), and with a software model based on an R404A refrigeration system installed in a supermarket in north east England. In both approaches the condenser fan power usage was excluded from the COP but included in the COSP. The results showed that, especially for part load conditions, optimising the core refrigeration system for minimum power consumption led to an appreciably higher overall energy consumption with the implication that the condenser fan and compressor controls should be developed together. When using this holistic approach it was found that energy savings of 4.5% could have been achieved based on six months' data from the installed system.
Available documents
Format PDF
Pages: 225-234
Available
Free
Details
- Original title: Illustrating the relationship between the coefficient of performance and the coefficient of system performance by means of an R404 supermarket refrigeration system.
- Record ID : 30018697
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 70
- Publication date: 2016/10
Links
See other articles in this issue (25)
See the source
-
Comparing COP optimization with maximizing the ...
- Author(s) : BRAUN M. R., BECK S. B. M., ALTAN H.
- Date : 2014/07/14
- Languages : English
- Source: 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Régulation intelligente des installations frigo...
- Author(s) : LINDHARD B.
- Date : 2001
- Languages : French
- Source: Danfoss J. - n. 2
View record
-
Mezclas HFC/HFO para sustituir al R404A en refr...
- Author(s) : MOTA BABILONI A., BARRAGÁN-CERVERA A., NAVARRO-ESBRÍ J., et al.
- Date : 2016/05/03
- Languages : Spanish
- Source: CYTEF 2016. VIII Congreso Ibérico y VI Congreso Iberoamericano de las Ciencias y Técnicas del Frío, Coimbra-Portugal, 3-6 mayo, 2016.
- Formats : PDF
View record
-
New type of energy efficient heat exchanger for...
- Author(s) : HAGLUND STIGNOR C., TILJANDER P., LINDBERG U., et al.
- Date : 2018/04/06
- Languages : English
- Source: 5th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Beijing, Chine, 6-8 avril 2018
- Formats : PDF
View record
-
Post HCFC22 commercial refrigeration sector in ...
- Author(s) : SOOBEN D., MOHEE R., MEUNIER F.
- Date : 2014/08/02
- Languages : English
- Source: 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF