Document IIF
Infiltration de l'air à travers les portes des chambres froides.
Air infiltration into walk-in cold rooms through doors.
Numéro : pap. n. 751
Auteurs : CLELAND D. J., EAST A. R., JEFFERY P. B.
Résumé
The air infiltration through doors into two walk-in cold rooms was measured for a range of door opening scenarios likely to occur in practice. Door air-tightness when closed was better than for larger forklift doors. Infiltration rates if the doors were only opened to 45° rather than 90° from the wall were not significantly different but if doors were only left ajar the rate was considerably lower; although still large compared with closed doors. Strip curtains provided an effective method to reduce air infiltration and their effectiveness was only slightly reduced by foot traffic through the door. If the predictions were adjusted by the door fractional open time, Gosney & Olama’s equation provided useful predictions of average air infiltration rates for personnel doors into walk-in cold rooms with a correction factor of between 0.4 and 0.6.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Air infiltration into walk-in cold rooms through doors.
- Identifiant de la fiche : 30015533
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Date d'édition : 16/08/2015
- DOI : http://dx.doi.org/10.18462/iir.icr.2015.0751
Liens
Voir d'autres communications du même compte rendu (657)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Entrepôts frigorifiques : conception, construction, isolation et équipement
- Mots-clés : Étancheite; Chambre froide; Mesure; Rideau d'air; Air
-
Flow regimes and thermal patterns in cold rooms.
- Auteurs : ABOU ZIED A., EL-HARRIRY G., KHALIL E. E.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
VOLET D'AIR POUR UNE CHAMBRE FROIDE A LARGE OUV...
- Auteurs : FUKUHARA I., TSUJI K.
- Date : 1988
- Langues : Japonais
- Source : Trans. JAR - vol. 5 - n. 3
Voir la fiche
-
ETUDE EXPERIMENTALE DU RIDEAU D'AIR DANS LES CH...
- Auteurs : NICULITA P., PURICE N., CIOBANU A.
- Date : 1984
- Langues : Roumain
- Source : Lucr. Cercet. Inst. Chim. aliment. - 14; 1982 (publ. 1984); 67-76; 8 fig.; 1 tabl.; 7 ref.
Voir la fiche
-
EXPERIENCE DE REMISE EN ETAT DE L'ISOLATION THE...
- Auteurs : GORJACEV B. I., DZUGIS S. S., DREVAL Ju. K.
- Date : 1984
- Langues : Russe
- Source : Kholodilnaya Tekhnika - n. 5
Voir la fiche
-
Rideau pour les entrées d'air.
- Auteurs : AZZOUZ A.
- Date : 04/1997
- Langues : Français
- Source : La revue pratique du froid et du conditionnement d'air - n. 845
Voir la fiche