Document IIF
Influence des températures de la source et du puits thermique et de la charge optimale en frigorigène d'une pompe à chaleur eau-eau.
Influence of the source and sink temperatures of the optimal refrigerant charge of a water-to-water heat pump.
Auteurs : CORBERÁN J. M., MARTÍNEZ-GALVÁN I., GONZÁLVEZ-MACIÁ J., et al.
Résumé
This paper presents the results of a simulation study that was carried out in order to elucidate the influence of the source and sink temperatures on the optimal charge of a water-to-water heat pump. A water to water chiller previously employed in a charge optimisation study carried out by the authors, was modelled in detail with IMST-ART software and a full simulation study was performed, first as a chiller, keeping constant the outlet water temperature from the evaporator at 7ºC replicating the experimental campaign, and then as a heat pump, keeping constant the hot water supply temperature at the outlet of the condenser, replicating the test campaign carried out with a water to water heat pump at KTH (Stockholm). The results of the simulations were in very good agreement with the test results obtained at UPV when the sink temperatures (condensation temperatures) were varied, and show the same trends found at KTH when the source temperature (evaporation temperature) was progressively decreased. The simulation allowed to study the refrigerant distribution among the different components of the system at different operating conditions and showed that the great variation of the optimal charge with the variation of the evaporation temperature is mainly due to the variation of the amount of refrigerant into the oil. Regarding the refrigerant distribution among the components, most of the charge was found in the condenser (50-80%), a considerable part in the evaporator (around 15%) and a substantial amount in the compressor oil (10-35%).
Documents disponibles
Format PDF
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Influence of the source and sink temperatures of the optimal refrigerant charge of a water-to-water heat pump.
- Identifiant de la fiche : 2009-1778
- Langues : Anglais
- Source : RCR 2009. 1st IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems.
- Date d'édition : 06/04/2009
Liens
Voir d'autres communications du même compte rendu (26)
Voir le compte rendu de la conférence
-
Investigation on the performance change of a he...
- Auteurs : JEONG Y., LEE S., KIM M. S.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Theoretical analysis of the impacts of refriger...
- Auteurs : CHEN G., FANG J., LI Z., ZHANG S.
- Date : 03/2023
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 147
- Formats : PDF
Voir la fiche
-
Propan-Abluft-Wärmepumpe mit minimaler Kältemit...
- Auteurs : OTT S., FRICK H.
- Date : 21/11/2007
- Langues : Allemand
- Source : DKV-Tagungsbericht 2007, Hannover.
Voir la fiche
-
Performance evaluation of a non-adiabatic capil...
- Auteurs : AGRAWAL N., BHATTACHARYYA S.
- Date : 04/2008
- Langues : Anglais
- Source : International Journal of thermal Sciences - vol. 47 - n. 4
Voir la fiche
-
Performance optimization of a transcritical car...
- Auteurs : AGRAWAL N., BHATTACHARYYA S.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche