IIR document
Influence of the source and sink temperatures of the optimal refrigerant charge of a water-to-water heat pump.
Author(s) : CORBERÁN J. M., MARTÍNEZ-GALVÁN I., GONZÁLVEZ-MACIÁ J., et al.
Summary
This paper presents the results of a simulation study that was carried out in order to elucidate the influence of the source and sink temperatures on the optimal charge of a water-to-water heat pump. A water to water chiller previously employed in a charge optimisation study carried out by the authors, was modelled in detail with IMST-ART software and a full simulation study was performed, first as a chiller, keeping constant the outlet water temperature from the evaporator at 7ºC replicating the experimental campaign, and then as a heat pump, keeping constant the hot water supply temperature at the outlet of the condenser, replicating the test campaign carried out with a water to water heat pump at KTH (Stockholm). The results of the simulations were in very good agreement with the test results obtained at UPV when the sink temperatures (condensation temperatures) were varied, and show the same trends found at KTH when the source temperature (evaporation temperature) was progressively decreased. The simulation allowed to study the refrigerant distribution among the different components of the system at different operating conditions and showed that the great variation of the optimal charge with the variation of the evaporation temperature is mainly due to the variation of the amount of refrigerant into the oil. Regarding the refrigerant distribution among the components, most of the charge was found in the condenser (50-80%), a considerable part in the evaporator (around 15%) and a substantial amount in the compressor oil (10-35%).
Available documents
Format PDF
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Influence of the source and sink temperatures of the optimal refrigerant charge of a water-to-water heat pump.
- Record ID : 2009-1778
- Languages: English
- Source: RCR 2009. 1st IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems.
- Publication date: 2009/04/06
Links
See other articles from the proceedings (26)
See the conference proceedings
Indexing
-
Analysis of the refrigerant‐side temperature pr...
- Author(s) : SIERES J., ORTEGA I., CERDEIRA F., SANTOS J. M., ALVAREZ E.
- Date : 2023/08/21
- Languages : English
- Source: Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
View record
-
A theoretical refrigerant charge prediction equ...
- Author(s) : HONG S. B., YOO J. W., KIM M. S.
- Date : 2019/08
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 104
- Formats : PDF
View record
-
Alternative cycle time control methods for vari...
- Author(s) : ROBBINS T. R., GARIMELLA S.
- Date : 2011/04/06
- Languages : English
- Source: Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
View record
-
Performance evaluation of a non-adiabatic capil...
- Author(s) : AGRAWAL N., BHATTACHARYYA S.
- Date : 2008/04
- Languages : English
- Source: International Journal of thermal Sciences - vol. 47 - n. 4
View record
-
Theoretical analysis of the impacts of refriger...
- Author(s) : CHEN G., FANG J., LI Z., ZHANG S.
- Date : 2023/03
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 147
- Formats : PDF
View record