Document IIF

Intégration d'une turbine à détente triétagée dans un système frigorifique au CO2.

Integration of a three-stage expander into a CO2 refrigeration system.

Auteurs : QUACK H., KRAUS W. E., NICKL J., et al.

Résumé

The inclusion of an expander with work recovery provides two advantages for transcritical CO2 refrigeration cycles: The COP is improved and the exhaust pressure of the main compressor is lowered. Several designs of expanders have been proposed for this application and some prototypes have been tested already. This paper deals with the question, how such an expander could be integrated into the overall system, where it should be located and how the "condensate" should be distributed to the different cooling locations. For optimum integration into the overall system it is proposed to install a vapour-liquid separator between the second and third stage of expansion. The vapour would be guided back to the third expander stage whereas the liquid is supplied to the cooling stations via thermostatic or electronic expansion valves or stored in a receiver.

Documents disponibles

Format PDF

Pages : 2004-2

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Integration of a three-stage expander into a CO2 refrigeration system.
  • Identifiant de la fiche : 2005-1771
  • Langues : Anglais
  • Source : Natural Working Fluids 2004: 6th IIR-Gustav Lorentzen Conference
  • Date d'édition : 01/08/2004

Liens


Voir d'autres communications du même compte rendu (105)
Voir le compte rendu de la conférence