Résumé
Embraco for many years is present as a one of the more active companies in promoting hermetic compressors for use with natural refrigerants worldwide. Apart of isobutane in household type of appliances, propane is becoming the main option in light commercial plug-in systems as R404A and R134a natural alternative. Recent F-Gas EU regulation as well as similar legislation in other parts of the planet, in order to mitigate climate change, are considering ban of high GWP refrigerants in next few years in majority of categories of commercial refrigeration applications.
Apart of hydrocarbons many alternative synthetic refrigerants are becoming available. Embraco performed a number of activities to assess their capacity to replace high GWP refrigerants presently in use. This paper will summarize present state of art in alternatives testing in A1 class as well as new A2L class refrigerants and will demonstrate clear superiority of natural refrigerants over synthetic options. Focus will be given to reliability aspects rather than to cooling capacity and efficiency. An update of the progress of international legislation related to use of higher charges of flammable products will be presented..
Documents disponibles
Format PDF
Pages : 6
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Low GWP refrigerants era has started – Compressor manufacturer experience.
- Identifiant de la fiche : 30022393
- Langues : Anglais
- Sujet : Réglementation, Alternatives aux HFC
- Source : Compressors 2017: 9th International Conference on Compressors and Coolants.
- Date d'édition : 06/09/2017
- DOI : http://dx.doi.org/10.18462/iir.compr.2017.0217
Liens
Voir d'autres communications du même compte rendu (35)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Compresseurs;
HFC;
Hydrocarbures;
Frigorigènes, frigoporteurs : réglementation et normes - Mots-clés : Réglementation; R600a; R134a; R404A; Synthèse; Inflammabilité; HFC; GWP
-
Equipment for refrigerants with lower (A2L) and...
- Auteurs : AREA, BUONI M.
- Date : 04/2016
- Langues : Anglais
Voir la fiche
-
Attrezzatura per refrigeranti a bassa (A2l) ed ...
- Auteurs : AREA, BUONI M.
- Date : 04/2016
- Langues : Italien
Voir la fiche
-
Düsük (A2l) ve yüksek (A3) tutusma potansiyelin...
- Auteurs : AREA, BUONI M.
- Date : 04/2016
- Langues : Turc
Voir la fiche
-
Performance comparison of very low GWP R404A al...
- Auteurs : SPLETZER S., MEDINA J., ROBERTS N.
- Date : 06/09/2017
- Langues : Anglais
- Source : Compressors 2017: 9th International Conference on Compressors and Coolants.
- Formats : PDF
Voir la fiche
-
Czynniki chlodnicze o niskim potencjale GWP a k...
- Auteurs : CLODIC D.
- Date : 10/2010
- Langues : Polonais
- Source : Chlodnictwo - vol. 45 - n. 10
Voir la fiche