Document IIF
Le CO2 appliqué aux supermarchés. Une nouvelle solution et conception de système pour la suralimentation des évaporateurs dans les meubles de vente et les chambres froides dans un système « booster » transcritique.
Supermarket application with CO2. New solution and system design for the evaporators overfeeding in cabinet and cold rooms in transcritical booster.
Numéro : pap. 1231
Auteurs : BIGARAN H., DE BONA M., MAZZOLA D.
Résumé
Natural refrigerants are today more and more proposed as a ready to use solution in commercial refrigeration. For this reason there is a constant technological improvement of “green” system, with special reference to CO2 trans critical installations. The key to success is to simplify trans critical technology and enhance efficiency and reliability. This paper present a new solution called FTE (Full Trans critical Efficiency) that has been developed in order to increase reliability and efficiency in a simple design of the system. This solution adds to the system an intermediate liquid receiver located between refrigerated cabinet and the compressors which permits to overfeed the refrigerated loads operating without any superheat and, as consequence, to increase the evaporator temperature and the efficiency. This additional intermediate liquid receiver collects the liquid that’s coming out from the refrigerated loads and delivers the liquid accumulated directly to the frozen loads. FTE is a system solution that can be adopted in all the climates and that increase the efficiency during the whole year. This study has the scope to describe and demonstrate the benefit of the FTE comparing to standard trans critical system. To support the theoretical analysis real consumption of a store installed in South of Europe will be highlighted.
Documents disponibles
Format PDF
Pages : 9
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Supermarket application with CO2. New solution and system design for the evaporators overfeeding in cabinet and cold rooms in transcritical booster.
- Identifiant de la fiche : 30023638
- Langues : Anglais
- Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Date d'édition : 18/06/2018
- DOI : http://dx.doi.org/10.18462/iir.gl.2018.1231
Liens
Voir d'autres communications du même compte rendu (177)
Voir le compte rendu de la conférence
Indexation
-
Experimental investigation of PCM location in a...
- Auteurs : YILMAZ D., MANCUHAN E., YILMAZ B.
- Date : 12/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 120
- Formats : PDF
Voir la fiche
-
Influence of cooling load profile on the predic...
- Auteurs : D'AGARO P., LIBRALATO M., TOFFOLETTI G., CORTELLA G.
- Date : 13/06/2022
- Langues : Anglais
- Source : 15th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2022). Proceedings. Trondheim, Norway, June 13-15th 2022.
- Formats : PDF
Voir la fiche
-
Performance of an integral display cabinet work...
- Auteurs : ABDALLAH R. ben, LEDUCQ D., HOANG H. M., et al.
- Date : 06/04/2018
- Langues : Anglais
- Source : 5th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Beijing, Chine, 6-8 avril 2018
- Formats : PDF
Voir la fiche
-
Experimental analysis of refrigeration CO2...
- Auteurs : NEBOT-ANDRÉS L., CALLEJA-ANTA D., SÁNCHEZ D., CABELLO R., LLOPIS R.
- Date : 13/06/2022
- Langues : Anglais
- Source : 15th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2022). Proceedings. Trondheim, Norway, June 13-15th 2022.
- Formats : PDF
Voir la fiche
-
CO2 : la solution pérenne en matière de fluide ...
- Auteurs : PONDICQ-CASSOU N., HEINBOKEL B., BURVINGT G.
- Date : 04/2014
- Langues : Français
- Source : Revue générale du Froid & du Conditionnement d'air - vol. 104 - n. 1142
Voir la fiche