Mélanges d'hydrocarbures et de R134a et R600a comme frigorigènes de remplacement immédiat pour les appareils commerciaux de petite puissance : étude expérimentale.

Hydrocarbon blends and blends of R134a-R600a as drop-in refrigerants for small capacity commercial refrigeration appliance: an experimental study.

Auteurs : AGARWAL R. S.

Résumé

The paper presents a thermodynamic study of hydrocarbon blends (propane/isobutane) and blends of R134a-R600a as a possible "drop-in" (some electrical components to be changed to make the appliance safe) substitute to R12. Extensive experimental work has been carried out to evaluate the performance of the proposed blends for small capacity commercial refrigeration appliances such as bottle coolers. The results show that the hydrocarbon blend with 50 percent by mass of isobutane and the R134a-R600a mixture are potential drop-in candidates.

Détails

  • Titre original : Hydrocarbon blends and blends of R134a-R600a as drop-in refrigerants for small capacity commercial refrigeration appliance: an experimental study.
  • Identifiant de la fiche : 1999-3370
  • Langues : Anglais
  • Source : Proceedings of the 1998 Purdue International Refrigeration Conference.
  • Date d'édition : 14/07/1998
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres communications du même compte rendu (67)
Voir le compte rendu de la conférence