Résumé
An experimental study was conducted on the part load ratio (PLR), part load factor (PLF), and degradation coefficient (CD) values in the cyclic operation condition of an air conditioner by simulating the sensible building load of an indoor room in a well-defined chamber environment. When constant and variable speed air conditioners were cyclically operated at a fixed set temperature with various building load stages, the coefficient values of PLR, PLF, and CD were recorded and analyzed. The values captured by this novel experimental approach showed consistency, with relatively small measurement errors compared with prior studies. Our experimental data could be used as reasonable evidence data in the seasonal efficiency calculation method of UNI, ASHRAE, EN, ISO, and other air conditioner standards.
Documents disponibles
Format PDF
Pages : 8
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental measurement of cyclic degradation performance of air conditioners through a building load simulation in a test chamber environment.
- Identifiant de la fiche : 30028916
- Langues : Anglais
- Sujet : Technologie
- Source : 6th IIR Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Date d'édition : 01/09/2021
- DOI : http://dx.doi.org/10.18462/iir.TPTPR.2021.1990
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres communications du même compte rendu (48)
Voir le compte rendu de la conférence
-
Comparison of steady-state and dynamic load-bas...
- Auteurs : DHILLON P., HORTON W. T., BRAUN J. E.
- Date : 05/2021
- Langues : Anglais
- Source : 2021 Purdue Conferences. 18th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Guidelines for the safe use of flammable refrig...
- Auteurs : CROISET I. C., LECHTENBÖHMER C., NASSANO P.
- Date : 02/2012
- Langues : Anglais
Voir la fiche
-
Demonstration of a load-based testing methodolo...
- Auteurs : DHILLON P., HORTON W. T., BRAUN J. E.
- Date : 05/2021
- Langues : Anglais
- Source : 2021 Purdue Conferences. 18th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Verschenktes Potenzial: Praxiserfahrungen mit d...
- Auteurs : STROBEL R.
- Date : 10/06/2011
- Langues : Allemand
- Source : CCI Zeitung - vol. 45 - n. 7
- Formats : PDF
Voir la fiche
-
Evaluating the impact of the measurement setup ...
- Auteurs : DHUMANE R., QIU T., LING J., et al.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche