IIR document
Experimental measurement of cyclic degradation performance of air conditioners through a building load simulation in a test chamber environment.
Number: 1990
Author(s) : YOON M. S., YOON W. S.
Summary
An experimental study was conducted on the part load ratio (PLR), part load factor (PLF), and degradation coefficient (CD) values in the cyclic operation condition of an air conditioner by simulating the sensible building load of an indoor room in a well-defined chamber environment. When constant and variable speed air conditioners were cyclically operated at a fixed set temperature with various building load stages, the coefficient values of PLR, PLF, and CD were recorded and analyzed. The values captured by this novel experimental approach showed consistency, with relatively small measurement errors compared with prior studies. Our experimental data could be used as reasonable evidence data in the seasonal efficiency calculation method of UNI, ASHRAE, EN, ISO, and other air conditioner standards.
Available documents
Format PDF
Pages: 8
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Experimental measurement of cyclic degradation performance of air conditioners through a building load simulation in a test chamber environment.
- Record ID : 30028916
- Languages: English
- Subject: Technology
- Source: 6th IIR Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Publication date: 2021/09/01
- DOI: http://dx.doi.org/10.18462/iir.TPTPR.2021.1990
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (48)
See the conference proceedings
Indexing
-
Performances of transport refrigeration units a...
- Author(s) : SUQUET T., CAVALIER G.
- Date : 2015/08/16
- Languages : English
- Source: Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
View record
-
Evaluating the impact of the measurement setup ...
- Author(s) : DHUMANE R., QIU T., LING J., et al.
- Date : 2018/07/09
- Languages : English
- Source: 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Energy saving effect of series connection pumps...
- Author(s) : ZHAO F., SUMIYOSHI D.
- Date : 2016/05
- Languages : Japanese
- Source: Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan - n. 230
View record
-
Load-based testing of heating and cooling equip...
- Author(s) : FRIDLYAND A., GUADA A. B., KUMAR N., AHSAN A., KINGSTON T., GLANVILLE P.
- Date : 2022
- Languages : English
- Source: 2022 Purdue Conferences. 19th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Investigation on the efficiency degradation cha...
- Author(s) : XU Z., HAO L., XU W., SHAO S., WANG Z., GOU X., ZHAO M., LI J.
- Date : 2022/01
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 133
- Formats : PDF
View record