Résumé
Measuring AERs in an effective, real-time, easy and low-cost way is still a challenge, especially in China where rooms were usually naturally ventilated but not with the heating, ventilating and air-conditioning system. A new AER monitoring method using continuous CO2 sensor was validated through both laboratory experiments and field studies. Controlled laboratory simulation tests were conducted in a 1 m3 environmental chamber at different AERs. AERs were determined using steady-state method and decay method based on box model assumptions. Field tests were conducted in apartments, offices, classrooms, dormitories and meeting rooms in during 3-5 weekdays with four sets of sensors coupled with data loggers. Statistic results indicated that good laboratory performance was achieved. In spite of limitations, this new method, along with mini-sized and easily operational instrumentations which provide sufficient continuous data, demonstrated an effective way to measure AERs in various indoor environments.
Détails
- Titre original : Measuring air exchanges rates using continuous CO2 sensors.
- Identifiant de la fiche : 2008-2617
- Langues : Anglais
- Source : Clima 2007. WellBeing Indoors. Proceedings of the 9th REHVA World Congress [CD-ROM + Abstract book].
- Date d'édition : 10/06/2007
Liens
Voir d'autres communications du même compte rendu (76)
Voir le compte rendu de la conférence
Indexation
-
Analytical prediction of carbon dioxide concent...
- Auteurs : SELMAN S., DYER D.
- Date : 10/06/2007
- Langues : Anglais
- Source : Clima 2007. WellBeing Indoors. Proceedings of the 9th REHVA World Congress [CD-ROM + Abstract book].
Voir la fiche
-
Impianti a portata variabile per il controllo d...
- Auteurs : PEDRANZINI F., JOPPOLO C. M., PASINI A.
- Date : 07/03/2002
- Langues : Italien
- Source : Qualità ambientale e soluzioni sostenibili. 43e Convegno Internazionale AICARR [CD-ROM]./ Environmental quality and sustainable technology. 43rd International conference of AICARR [CD-ROM].
Voir la fiche
-
Etude concernant l'air frais dans les wagons de...
- Auteurs : ZHU P., ZHU Y.
- Date : 03/2006
- Langues : Chinois
- Source : HV & AC - vol. 36 - n. 183
- Formats : PDF
Voir la fiche
-
Energy efficient ventilation systems.
- Auteurs : TIMÁR G.
- Date : 10/06/2007
- Langues : Anglais
- Source : Clima 2007. WellBeing Indoors. Proceedings of the 9th REHVA World Congress [CD-ROM + Abstract book].
Voir la fiche
-
Measuring IAQ parameters.
- Auteurs : BEARG D. W.
- Date : 08/2008
- Langues : Anglais
- Source : HPAC Engineering - vol. 80 - n. 8
Voir la fiche