Document IIF

Méthode de co-chauffage pour l'évaluation des performances thermiques des meubles frigorifiques de vente fermés.

Co-Heating method for thermal performance evaluation of closed refrigerated display cabinets.

Auteurs : MANSSON T., SASIC KALAGASIDIS A., OSTERMEYER Y.

Type d'article : Article de la RIF

Résumé

In this study, an application of the adapted Co-Heating methodology for thermal performance evaluation of closed refrigerated display cabinets (RDCs) has been presented. A novel test series comprising three experiments has been developed and demonstrated on a commercial RDC with four doors to evaluate the envelope heat transfer coefficient, thermal inertia, infiltration at idle state and dynamic infiltration caused by door operations. The latter two experiments were conducted in parallel with the condensate collection method for validation of the results for infiltration. It was concluded with good (<10%) conformance between the methods that the infiltration at idle state for the tested RDC is approximately 0.022 kg/s and that one 15 s door opening causes approximately 0.94 of ambient indoor air to infiltrate. Additionally, the time, equipment and associated costs for running the tests were compared, and it was concluded that the adapted Co-Heating methodology could substitute the condensate collection method for the evaluation of infiltration while providing additional results on the thermal performance.

Documents disponibles

Format PDF

Pages : 51-60

Disponible

Gratuit

Détails

  • Titre original : Co-Heating method for thermal performance evaluation of closed refrigerated display cabinets.
  • Identifiant de la fiche : 30028013
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 121
  • Date d'édition : 01/2021
  • DOI : http://dx.doi.org/10.1016/j.ijrefrig.2020.10.011

Liens


Voir d'autres articles du même numéro (31)
Voir la source