Recommandé par l'IIF / Document IIF

Modélisation d'un système frigorifique de supermarché utilisant un frigorigène à faible potentiel de réchauffement planétaire (PRP) et son application.

Low global warming potential (GWP) refrigerant supermarket refrigeration system modeling and its application.

Auteurs : SUN J., KURUGANTI T., MUNK J., DONG J., CUI B.

Type d'article : Article de la RIF

Résumé

As an environmentally friendly low global warming potential (GWP) refrigerant, Carbon dioxide (CO2) has continuously gained popularity and research attention as alternative refrigerant for supermarket refrigeration system. In this paper, to fulfill the increasing need of accurate Low-GWP supermarket refrigeration models for development of supervisory level control and optimization strategies, a high fidelity model is developed for CO2 transcritical supermarket refrigeration system which includes compressor rack of low temperature (LT) compressors and medium temperature (MT) compressors, air-cooled gas cooler, evaporator, expansion valves and other auxiliary equipment. A resistance-capacity model structure is proposed to simulate the display cases. Semi-thermodynamic models are proposed to estimate reciprocating compressors volumetric efficiency and power consumption. The zone modeling approach is used for evaporator simulation, and air-cooled gas cooler is modeled with distributed modeling method. The expansion valve simulation is based on orifice flow model. To calibrate these models, both manufacture performance data and experimental data are used. The experiments are conducted with a full instrumental CO2 supermarket refrigeration system installed in Oak Ridge National Lab Flexible Research Platform (FRP). The simulation model can predict the system performance, including power consumption, cooling capacity, mass flow rate, temperature, and pressure, with high accuracy (within ±4%) compared to experimental data. In addition, this developed model has been used to create the system optimum high side pressure for high side expansion valve control, and to generate wide operating range simulation data for developing the batter-equivalent commercial refrigeration system model which can be used in grid interactive control development.

Documents disponibles

Format PDF

Pages : 195-209

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Low global warming potential (GWP) refrigerant supermarket refrigeration system modeling and its application.
  • Identifiant de la fiche : 30028298
  • Langues : Anglais
  • Sujet : Technologie
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 126
  • Date d'édition : 06/2021
  • DOI : http://dx.doi.org/10.1016/j.ijrefrig.2020.12.037

Liens


Voir d'autres articles du même numéro (25)
Voir la source