Résumé
Single and double row parallel-flow condensers had been used in the refrigerated display cabinet. This system was compared to the refrigerator system which used fin-and-tube condenser. This study show that the compressor average power consumption in a cycle was minimum when refrigerant was charged 550g, 650g and 800g respectively in the refrigerator systems which used single, double row parallel-flow and fin-and-tube condensers. The system with double row parallel-flow condenser consumed the least power among the three systems, and the system with single row parallel-flow condenser was almost the same with the system with fin-and-tube condenser. In the air side, parallel-flow condensers’ performance was better than the fin-and-tube condenser. The single and double row parallel-flow condensers only have a quarter and a half volume of the fin-and-tube condenser in the experiment, which indicates that parallel-flow condenser will be a good solution for the insufficient heat exchange capacity in the harsh environment and reduction of the cost when applied in refrigerator.
Documents disponibles
Format PDF
Pages : 83-90
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : [In Chinese. / En chinois.]
- Identifiant de la fiche : 30010100
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 34 - n. 151
- Date d'édition : 06/2013
- DOI : http://dx.doi.org/10.3969/j.issn.0253-4339.2013.03.083
Liens
Voir d'autres articles du même numéro (9)
Voir la source
Indexation
-
Experimental analysis of a standard and a low r...
- Auteurs : MASTRULLO R., MAURO A. W., MENNA L., et al.
- Date : 25/10/2012
- Langues : Anglais
- Source : RCR 2012. 3rd IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems: Valencia, Spain, October 25-26, 2012.
- Formats : PDF
Voir la fiche
-
Working fluid charge reduction. 1. CO2 fin-tube...
- Auteurs : MARCINICHEN J. B., THOME J. R., HORN-PEREIRA R.
- Date : 05/2016
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 65
- Formats : PDF
Voir la fiche
-
Modelling and analysis of CO2 gas coolers for c...
- Auteurs : SANTOSA I. M. C., SUAMIR I., GE Y. T., et al.
- Date : 02/04/2013
- Langues : Anglais
- Source : 2nd IIR International Conference on Sustainability and the Cold Chain. Proceedings: Paris, France, April 2-4, 2013.
- Formats : PDF
Voir la fiche
-
Improvement of two-phase refrigerant distributi...
- Auteurs : KIM N. H., LEE E. J., BYUN H. W.
- Date : 09/2013
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 59 - n. 1-2
Voir la fiche
-
Experimental study on parallel flow evaporators...
- Auteurs : LIANG Y., CHEN J. P.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche