Recommandé par l'IIF / Document IIF
Modélisation numérique dynamique d’une unité frigorifique avec éjecteur au R-744 monoétagé à double température pour la livraison du dernier kilomètre.
Dynamic numerical modelling of a single stage dual temperature R744 ejector-supported refrigeration unit for last mile delivery.
Numéro : 0810
Auteurs : FABRIS F., BODYS J., MARINETTI S., MINETTO S., SMOLKA J., ROSSETTI A.
Résumé
A novel design of a R744 vapor-compression refrigeration unit is proposed and developed to provide cooling capacity at two different temperature levels, in the range of 4-5 kW of MT refrigeration at 0°C and 1-2 kW of LT refrigeration at -20°C, inside the insulated box mounted on a typical medium-size refrigerated truck. Such a system can be employed for multi-temperature (chilled and frozen) goods transport to enhance the range of ambient conditions served with highly efficient operation during last-mile deliveries in urban environment.
The main innovation of the proposed cycle is related to the presence of a single compression stage with two different evaporation levels. Firstly, the cooling system design is based on the implementation of a MT ejector, with the purpose of energy efficiency improvement of the system due to the consequent reduction of the compressor pressure ratio. Secondly, an implemented LT ejector allows for the production of LT cooling effect with a single stage compressor. The system can switch to a back-pressure cycle once the ambient temperature is not sufficient to sustain the ejector cycle. On the other hand, the use of an ejector for the LT cycle allows to extend the application field of the single stage compressor to high ambient temperatures.
A dynamic numerical model of the refrigerating system has been developed to assess the system performance in ejector and back pressure mode. The numerical model was also used to characterize the system pull-down from ambient temperature.
Documents disponibles
Format PDF
Pages : 11
Disponible
Gratuit
Détails
- Titre original : Dynamic numerical modelling of a single stage dual temperature R744 ejector-supported refrigeration unit for last mile delivery.
- Identifiant de la fiche : 30031363
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Date d'édition : 21/08/2023
- DOI : http://dx.doi.org/10.18462/iir.icr.2023.0810
Liens
Voir d'autres communications du même compte rendu (491)
Voir le compte rendu de la conférence
Indexation
-
Experimental evaluation of the performance of a...
- Auteurs : FABRIS F., PARDIÑAS A. A., MARINETTI S., ROSSETTI A., HAFNER A., MINETTO S.
- Date : 13/06/2022
- Langues : Anglais
- Source : 15th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2022). Proceedings. Trondheim, Norway, June 13-15th 2022.
- Formats : PDF
Voir la fiche
-
A novel refrigeration system for refrigerated t...
- Auteurs : ZHAO P., JIA L., ZHANG X., et al.
- Date : 06/04/2018
- Langues : Anglais
- Source : 5th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Beijing, Chine, 6-8 avril 2018
- Formats : PDF
Voir la fiche
-
Numerical investigation on the thermal performa...
- Auteurs : ARTUSO P., ROSSETTI A., MINETTO S., et al.
- Date : 11/04/2019
- Langues : Anglais
- Source : 8th Conference on Ammonia and CO2 Refrigeration Technology. Proceedings: Ohrid, North Macedonia, Avril 11-13, 2019.
- Formats : PDF
Voir la fiche
-
Numerical analysis of the thermal performance o...
- Auteurs : FABRIS F., ARTUSO P., MARINETTI S., MINETTO S., ROSSETTI A.
- Date : 01/09/2021
- Langues : Anglais
- Source : 6th IIR Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Formats : PDF
Voir la fiche
-
Analysis of an advanced R744 cycle and its impa...
- Auteurs : KUJAK S., SCHULTZ K.
- Date : 18/06/2018
- Langues : Anglais
- Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Formats : PDF
Voir la fiche