Document IIF
Nouveaux échangeurs de chaleur destinés à des installations au CO2 à haut rendement.
New heat exchangers for high efficiency CO2 plants.
Numéro : pap. 1106
Auteurs : FILIPPINI S., MERLO U.
Résumé
CO2 refrigeration systems are now in widespread use in many applications, especially in the retail sector. In fact CO2 is an excellent, environmentally-friendly refrigerant which requires very efficient heat exchangers to reach high performance. LU-VE recently made developments with the aim of further improving the design of the finned heat exchanger, using also new technology with a very compact heat transfer matrix with tube diameter of only 5mm. The new heat exchanger configuration is designed both for gas coolers and unit coolers. The paper describes the activity of designing and testing the new geometry inside the CO2 test plant of the company. The new geometry provides an excellent balance between performance and reduced quantity of refrigerant in the circuit. A further development was made in the heat pump sector, in particular for supermarket applications. The decision to integrate the refrigeration and heating systems in these buildings is becoming increasingly common. However, in order to guarantee a sufficient quantity of heat to warm the supermarket even on the coldest days, with temperature below -10°C, an additional evaporator, positioned outside, must be added. This involves a special machine for which LU-VE has developed innovative technologies, capable of achieving very high levels of heat transfer efficiency, as described in this article.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : New heat exchangers for high efficiency CO2 plants.
- Identifiant de la fiche : 30019076
- Langues : Anglais
- Source : 12th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2016). Proceedings. Édimbourg, United Kingdom, August 21st-24th 2016.
- Date d'édition : 21/08/2016
- DOI : http://dx.doi.org/10.18462/iir.gl.2016.1106
Liens
- Voir les traductions : Nuevos intercambiadores de calor para plantas de CO2 de alta eficiencia.
Pasar de la G a la A+++ en equipos de baja temperatura comerciales.
Limpieza de circuitos frigoríficos para alargar la vida en las instalaciones existentes y mejorar su eficiencia energética.
Voir d'autres communications du même compte rendu (140)
Voir le compte rendu de la conférence
-
Nuevos intercambiadores de calor para plantas d...
- Auteurs : FILIPPINI S., MERLO U.
- Date : 01/2018
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 46 - n. 509
- Formats : PDF
Voir la fiche
-
Experimental analysis of an IHX in a CO2 subcri...
- Auteurs : LLOPIS R., SÁNCHEZ D., CABELLO R., et al.
- Date : 03/05/2016
- Langues : Anglais
- Source : CYTEF 2016. VIII Congreso Ibérico y VI Congreso Iberoamericano de las Ciencias y Técnicas del Frío, Coimbra-Portugal, 3-6 mayo, 2016.
- Formats : PDF
Voir la fiche
-
Electrochemical compressor for carbon dioxide.
- Auteurs : TAO Y., HWANG Y., RADERMACHER R., et al.
- Date : 18/06/2018
- Langues : Anglais
- Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Formats : PDF
Voir la fiche
-
Improvements of U-pipe borehole heat exchangers...
- Auteurs : ACUÑA J.
- Date : 2010
- Langues : Anglais
Voir la fiche
-
Innovative heat exchanger design for R717 and R...
- Auteurs : NAKAYAMA J.
- Date : 16/09/2021
- Langues : Anglais
- Source : 9th IIR Conference on Ammonia and CO2 Refrigeration Technologies. Proceedings: Ohrid, North Macedonia, 16-17 September, 2021
- Formats : PDF
Voir la fiche