Document IIF
Observation à l'aide d'imagerie de l'écoulement et de la distribution d'écoulements diphasiques dans un distributeur.
Flow observation and distribution of two-phase flow in a distributor.
Auteurs : MIYARA A., TSUBAKI K., SHIGETOMI T., et al.
Résumé
In order to understand flow configurations and distribution behaviour of gas and liquid two-phase flow in distributors, a basic experiment has been carried out for a two-path distributor by using air and water two-phase flow as working fluids. The two-path distributor was arranged so that one of the paths was downward and another was upward. Both the branches are parallel with each other and they have the same direction as the main channel. The inclination angle of the distributor was changed as horizontal, 30º and 60º. A fully developed air-water two-phase flow enters the main channel and is separated into the branches. The flow is upward when the distributor is inclined. Flow patterns in the main channel were stratified, slug, and annular according to the flow rates of air and water. Flow configurations during the separation were observed by a high-speed camera and effects of gravity and entrance flow pattern were investigated.
Documents disponibles
Format PDF
Pages : 2009-5
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Flow observation and distribution of two-phase flow in a distributor.
- Identifiant de la fiche : 2009-1952
- Langues : Anglais
- Source : 3rd Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Date d'édition : 23/06/2009
Liens
Voir d'autres communications du même compte rendu (66)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Transfert de chaleur;
Ecoulement diphasique - Mots-clés : Écoulement diphasique; Imagerie; Tuyauterie; Échangeur de chaleur; Distribution
-
Developing two-phase flow distribution in horiz...
- Auteurs : KOYAMA S., WIJAYANTA A. T., KUWAHARA K., et al.
- Date : 17/07/2006
- Langues : Anglais
- Source : 2006 Purdue Conferences. 18th International Compressor Engineering Conference at Purdue & 11th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
- Formats : PDF
Voir la fiche
-
Two-phase refrigerant distribution in a microch...
- Auteurs : BOWERS C. D., HRNJAK P. S., NEWELL T. A.
- Date : 17/07/2006
- Langues : Anglais
- Source : 2006 Purdue Conferences. 18th International Compressor Engineering Conference at Purdue & 11th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
- Formats : PDF
Voir la fiche
-
Numerical simulation of two-phase flow in multi...
- Auteurs : ABLANQUE N., OLIET C., RIGOLA J., et al.
- Date : 07/09/2008
- Langues : Anglais
- Source : 8th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2008)
- Formats : PDF
Voir la fiche
-
R-134a distribution in a header of a parallel f...
- Auteurs : KIM N. H., LEE E. R.
- Date : 21/05/2006
- Langues : Anglais
- Source : ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
Voir la fiche
-
Innovative experimental apparatus to measure li...
- Auteurs : ZIETLOW D., CAMPAGNA M., DIAS J.
- Date : 2002
- Langues : Anglais
- Source : ASHRAE Transactions. 2002 annual Meeting, Honolulu, Hawaii. Volume 108, part 2 + CD-ROM.
Voir la fiche