Document IIF
Performance en termes de refroidissement du frigorigène de remplacement R429A dans des purificateurs d'eau domestiques.
Cooling performance of alternative refrigerant R429A in domestic water purifiers.
Auteurs : PARK K. J., KANG D. G., JUNG D.
Résumé
In this study, cooling performance of R429A is examined both numerically and experimentally in an effort to replace HFC-134a used in the refrigeration system of domestic water purifiers. Even though HFC-134a is used predominantly in such a system these days, it needs to be phased out in near future in Europe and most of the developed countries due to its high global warming potential. To solve this problem, cycle simulation and experimental measurements are carried out with a new refrigerant mixture of R152a/E170/R600a (10/60/30) using actual domestic water purifiers. This mixture is numbered and listed as R429A by ASHRAE recently. Test results show that the system performance with R429A is greatly influenced by the amount of charge due to the small internal volume of the refrigeration system of the domestic water purifiers. With the optimum amount of charge of 21 grams, about 50% of HFC-134a, the energy consumption of R429A is 28.9% lower than that of HFC-134a. The compressor discharge temperature of R429A is 13.4°C lower than that of HFC-134a at the optimum charge. Overall, R429A, a new long term environmentally safe refrigerant, is a good alternative for HFC-134a requiring little change in the refrigeration system of the domestic water purifiers.
Documents disponibles
Format PDF
Pages : 2009-5
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Cooling performance of alternative refrigerant R429A in domestic water purifiers.
- Identifiant de la fiche : 2009-1920
- Langues : Anglais
- Source : 3rd Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Date d'édition : 23/06/2009
Liens
Voir d'autres communications du même compte rendu (66)
Voir le compte rendu de la conférence
Indexation
-
Performance evaluation of HFO-1234yf as a subst...
- Auteurs : LEE J. S., LEE M. R., JEON S.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche
-
Performance evaluation of HFO-1234yf as a subst...
- Auteurs : LEE J. S., LEE M. R., JEON S.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche
-
Experimental study of HC isobutane to replace r...
- Auteurs : CHANG W. R., SHAUT T. S., LIN C. H., et al.
- Date : 20/05/2009
- Langues : Anglais
- Source : ACRA-2009. The proceedings of the 4th Asian conference on refrigeration and air conditioning: May 20-22, 2009, Taipei, R.O.C.
- Formats : PDF
Voir la fiche
-
Experimental performance of R-1234yf and R-1234...
- Auteurs : KARBER K. M., ABDELAZIZ O., VINEYARD E. A.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
R152a versus R134a in domestic refrigerator-fre...
- Auteurs : SANVORDENKER K. S.
- Date : 14/07/1992
- Langues : Anglais