Performance thermique des vitres : méthode d'évaluation.

A test method to evaluate the thermal performance of window glazings.

Auteurs : ALVAREZ G., PALACIOS M. J., FLORES J. J.

Type d'article : Article

Résumé

During the test sequence, the glass samples are mounted in a specially designed calorimeter apparatus. The test is conducted in controlled laboratory conditions at the National Center for Research and Technology Development in Mexico using a solar simulator test lamp. The overall heat loss coefficient U(c) measured was of 1.7 plus or minus 0.1 W/m2 °C. Overall heat transfer and shading coefficients are derived from the experimental results. The test method described allows the testing of practically any kind of glazing array.

Détails

  • Titre original : A test method to evaluate the thermal performance of window glazings.
  • Identifiant de la fiche : 2001-1963
  • Langues : Anglais
  • Source : Applied Thermal Engineering - vol. 20 - n. 9
  • Date d'édition : 06/2000

Liens


Voir d'autres articles du même numéro (1)
Voir la source