A test method to evaluate the thermal performance of window glazings.

Author(s) : ALVAREZ G., PALACIOS M. J., FLORES J. J.

Type of article: Article

Summary

During the test sequence, the glass samples are mounted in a specially designed calorimeter apparatus. The test is conducted in controlled laboratory conditions at the National Center for Research and Technology Development in Mexico using a solar simulator test lamp. The overall heat loss coefficient U(c) measured was of 1.7 plus or minus 0.1 W/m2 °C. Overall heat transfer and shading coefficients are derived from the experimental results. The test method described allows the testing of practically any kind of glazing array.

Details

  • Original title: A test method to evaluate the thermal performance of window glazings.
  • Record ID : 2001-1963
  • Languages: English
  • Source: Applied Thermal Engineering - vol. 20 - n. 9
  • Publication date: 2000/06

Links


See other articles in this issue (1)