Performance thermique et accumulation d'humidité dans des systèmes d'isolation mécanique fonctionnant à des températures inférieures à la température ambiante sous conditions humides avec entrée d'humidité.
Thermal performance and moisture accumulation of mechanical pipe insulation systems operating at below ambient temperature in wet conditions with moisture ingress.
Numéro : pap. 3183
Auteurs : ZHU W., CAI S., CREMASCHI L.
Résumé
When pipes are used for chilled water, glycol brines, refrigerants, and other chilled fluids, energy must be spent to compensate for heat gains through the wall of the pipes. Higher fluid temperature at the point of use decreases the efficiency of the end-use heat exchangers and increases the parasitic energy consumption. Mechanical pipe insulation systems are often used to limit the heat gains and save energy in commercial buildings. Pipe insulation systems play an important role for the health of the occupied space. When a chilled pipe is uninsulated or inadequately insulated, condensation might occur and water will drip onto other building surfaces possibly causing mold growth. The critical issue with cold pipes is that the temperature difference between the pipe and its surrounding ambient air drives water vapor in to the insulation system and condensation commonly occurs when the water vapor comes in contact with the chilled pipe surface. This paper experimentally studies this issue for pipe insulation systems operating at below ambient temperature. The moisture content and the associated thermal conductivity of several pipe insulation systems were measured at various wet condensing conditions with moisture ingress. Accelerated type tests in laboratory showed the propensity of moisture accumulation in several insulation systems due to the cylindrical configuration, split joints, and micro-imperfections in the jacketing system. The data in the present work showed that the thermal conductivity increased systematically when water vapor entered the pipe insulation system.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Thermal performance and moisture accumulation of mechanical pipe insulation systems operating at below ambient temperature in wet conditions with moisture ingress.
- Identifiant de la fiche : 30013830
- Langues : Anglais
- Source : 2014 Purdue Conferences. 3rd International High Performance Buildings Conference at Purdue.
- Date d'édition : 14/07/2014
Liens
Voir d'autres communications du même compte rendu (66)
Voir le compte rendu de la conférence
Indexation
-
Moisture accumulation and its impact on the the...
- Auteurs : CAI S., CREMASCHI L., GHAJAR A. J.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 2nd International High Performance Buildings Conference at Purdue.
- Formats : PDF
Voir la fiche
-
CRITICAL FACTORS IN REFRIGERATION PIPELINE INSU...
- Auteurs : ADAMS G.
- Date : 1989
- Langues : Anglais
Voir la fiche
-
CONDENSATION CONTROL.
- Auteurs : WATSON P.
- Date : 1989
- Langues : Anglais
Voir la fiche
-
Innovative concept to prevent moisture formatio...
- Auteurs : KORSGAARD V.
- Date : 1993
- Langues : Anglais
- Source : ASHRAE Transactions 1993.
Voir la fiche
-
The thermal conductivity of cryogenic insulatio...
- Auteurs : HOFMANN A.
- Date : 11/2006
- Langues : Anglais
- Source : Cryogenics - vol. 46 - n. 11
Voir la fiche