Document IIF

Première installation pilote commerciale d'un chauffe-eau à pompe à chaleur fonctionnant au CO2 : expériences et résultats.

Results and experiences with the first commercial pilot plant CO2 heat pump water heater.

Auteurs : ZAKERI G. R., NEKSÅ P., REKSTAD H., et al.

Résumé

The first commercial pilot plant heat pump water heat with CO2 as working fluid has been built and installed in Norway by Frostmann a.s. in co-operation with SINTEF Energy Research, Refrigeration and Air Conditioning. In the evaporator (cascade heat exchanger), NH3 condenses (either partial or full condensation) giving up heat to evaporating CO2. The heat pump system produces hot water with temperature of 70-80 °C. The operating system is very stable, with very little variation in heat source temperature. A heating-COP of 5.77 is achieved when tap water is heated from 6.7 to 66 °C.

Documents disponibles

Format PDF

Pages : 2000-1

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Results and experiences with the first commercial pilot plant CO2 heat pump water heater.
  • Identifiant de la fiche : 2001-0684
  • Langues : Anglais
  • Source : Final proceedings of the 4th IIR-Gustav Lorentzen Conference on Natural Working Fluids at Purdue.
  • Date d'édition : 25/07/2000

Liens