Document IIF
Propriétés des frigorigènes à faible GWP en matière de sécurité.
Safety related properties of low-GWP refrigerants.
Numéro : pap. n. 767
Auteurs : ASKAR E., SCHRODER V., GÖPFERT T., et al.
Résumé
Most fluorinated hydrocarbons that shall replace refrigerants with high GWP, like R134a, are flammable. For evaluating inertization measures for explosion protection, flammability of low-GWP refrigerants R1234yf, R32 and R1132a blended with carbon dioxide, nitrogen and argon were studied experimentally in a closed autoclave at atmospheric conditions. Furthermore, a calculation method was adapted to reduce the experimental costs for flammability studies on these gas mixtures. For igniting R1234yf in the closed autoclave a newly developed ignition system was used that allows generating electric arcs with high ignition energy. Gas mixtures containing the mildly flammable R1234yf and R32 could be inerted by adding much less inert gas than mixtures containing R1132a, which is more similar to unfluorinated hydrocarbons regarding the explosion regions. By using the adapted model of constant adiabatic flame temperature profiles estimating the explosion limits of fluorinated hydrocarbons was possible with similar accuracy as for unfluorinated hydrocarbons.
Documents disponibles
Format PDF
Pages : 7
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Safety related properties of low-GWP refrigerants.
- Identifiant de la fiche : 30026032
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Date d'édition : 24/08/2019
- DOI : http://dx.doi.org/10.18462/iir.icr.2019.0767
Liens
Voir d'autres communications du même compte rendu (632)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
HFC;
Circulation du fluide : tuyauterie, régulation, automatisme, sécurité - Mots-clés : R1234yf; Sécurité; Calcul; Faible GWP; R32; Inflammabilité; Explosion; Frigorigène
-
Explosion characteristics of mildly flammable r...
- Auteurs : ASKAR E., SCHRODER V., SCHMID T., et al.
- Date : 06/2018
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 90
- Formats : PDF
Voir la fiche
-
AHRI research activities on flammable refrigera...
- Auteurs : WANG X.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche
-
AHRI research activities on flammable refrigera...
- Auteurs : WANG X.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche
-
Viability of various ignition sources to ignite...
- Auteurs : KIM D. K., SUNDERLAND P. B.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Combustion suppression effect of additives for ...
- Auteurs : HIGASHI T., DANG C., HIHARA E., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche