Document IIF
Recherche théorique et expérimentale sur une nouvelle stratégie de régulation du dégivrage basée sur un capteur de pression différentielle.
Theoretical and experimental research on a new defrosting control strategy based on differential pressure sensor.
Résumé
During system operation, frosting of the (heat pump and refrigerating) evaporator is inevitable. As such, the determination of the defrosting start time is integral for maintaining efficient and stable operation of the system. In the present study, a dimensionless parameter, pressure loss factor (PLF), was proposed based on the differential pressure sensor to determine the defrosting start time. For PLF, only the pressure difference before and after the evaporator needs to be measured, allowing for the growth trend of the frost layer on the evaporator to be quantitatively described. Firstly, through preliminary experiments, the optimal layout position of the differential pressure sensor was determined. Subsequently, the optimal defrosting time and PLF start threshold were determined based on the heat transfer rate of the evaporator. Under different experimental conditions, frosting experiments were conducted to validate the reliability of the proposed method. The results reveal that the optimal measuring point of the differential pressure sensor of the evaporator (with double fans) was on the central axis. The average error between the pressure difference at the measuring point and the average pressure difference of the evaporator was 2.76% under different experimental conditions. By using the PLF defrosting control method, the defrosting start time was accurately determined with the maximum error of ±5.5%.
Documents disponibles
Format PDF
Pages : 11-18
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Theoretical and experimental research on a new defrosting control strategy based on differential pressure sensor.
- Identifiant de la fiche : 30030327
- Langues : Anglais
- Sujet : Technologie
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 143
- Date d'édition : 11/2022
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2022.06.031
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres articles du même numéro (18)
Voir la source
-
A novel defrosting initiation strategy based on...
- Auteurs : WANG W., ZHOU Q., TIAN G., WANG Y., ZHAO Z., CAO F.
- Date : 08/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 128
- Formats : PDF
Voir la fiche
-
A review of the effects and mitigation of frost...
- Auteurs : MASHHADIAN A., ISMAIL T., BACH C. K., ALEXANDER A.
- Date : 10/07/2022
- Langues : Anglais
- Source : 2022 Purdue Conferences. 19th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Heat transfer correlations and pressure drop dy...
- Auteurs : NDUKWU M. C., MATTHEW I., GODWIN A., ORIAKU L., ABADA U. C., KALU C. A., EDETH BEN A., MBANASOR J., WU H.
- Date : 10/2023
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 154
- Formats : PDF
Voir la fiche
-
Development of energy saving cold storage wareh...
- Auteurs : CHOI K. I., CHIEN N. B., KIM K. W., et al.
- Date : 02/04/2013
- Langues : Anglais
- Source : 2nd IIR International Conference on Sustainability and the Cold Chain. Proceedings: Paris, France, April 2-4, 2013.
- Formats : PDF
Voir la fiche
-
GESTION DES STOCKS EN ENTREPOSAGE FRIGORIFIQUE.
- Auteurs : GAC A.
- Date : 05/1982
- Langues : Français
- Source : Rev. gén. Froid - vol. 72 - n. 5
Voir la fiche