Résumé

L'HUMIDITE, LA TEMPERATURE, LA TENEUR EN PARTICULES ET LA QUALITE MICROBIENNE DE L'AIR DOIVENT ETRE REGULEES DANS LA < ZONE A ENVIRONNEMENT CONTROLE > DE LA FABRICATION POUR S'ASSURER QUE LE MEDICAMENT CONSERVE SA PURETE. UN SYSTEME DE CONDITIONNEMENT D'AIR EN CIRCUIT OUVERT ET UNE FAIBLE HUMIDITE RELATIVE SONT DES BESOINS FREQUENTS. CET ARTICLE EXAMINE L'ECHANGE D'ENERGIE AIR-AIR OU LA CHALEUR SENSIBLE ET LA CHALEUR LATENTE SONT TRANSFEREES ENTRE LES DEUX FLUX D'AIR (RECUPERATION DE L'ENTHALPIE). ON CONSIDERE L'IMPACT SUR LE COUT D'INVESTISSEMENT, L'ECONOMIE D'ENERGIE ET LA PROPRETE DE L'AIR. LA RECUPERATION D'ENTHALPIE PAR ABSORPTION CHIMIQUE PEUT ETRE ASSEZ RENTABLE.

Détails

  • Titre original : ENTHALPY RECOVERY IN LOW-HUMIDITY PHARMACEUTICAL CLEAN ROOMS.
  • Identifiant de la fiche : 1988-0296
  • Langues : Anglais
  • Date d'édition : 1987
  • Source : Source : ASHRAE Trans.
    vol. 93; n. 1; 1319-1332; 9 fig.; 3 tabl.; 6 ref.
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.