Document IIF
Réduction de la charge en frigorigène d'un conditionneur d'air split au R22 fonctionnant au R290 dans des conditions d'essai domestique et pour l'exportation.
Charge reduction for a R22 split air conditioner operated with R290 under DT and ETB conditions.
Numéro : pap. 1021
Auteurs : SARAVANAN A. L., MOHAN LAL D., DURAISAMY A.
Résumé
As per Montreal Protocol R22 is to be phased out by 2030 AD in all Article 5 countries. Propane (R290) is a viable alternative for R22, but it is flammable. Hence attempts are made to reduce the charge quantity. This paper presents an experimental performance study of a split air conditioner with propane, as a substitute for R22. A split air conditioner of 5.25 kW capacity has been tested for energy efficiency in a Psychrometric test room under standard test conditions as per BIS-1391-1992 Part 2. Domestic test & Export Test B conditions were considered for this study. The results show that as the condenser tube diameter is reduced from 12.7 mm to 6.35mm, the optimum charge got reduced to 320 g and 310 g for DT & ETB conditions respectively.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Charge reduction for a R22 split air conditioner operated with R290 under DT and ETB conditions.
- Identifiant de la fiche : 30019047
- Langues : Anglais
- Source : 12th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2016). Proceedings. Édimbourg, United Kingdom, August 21st-24th 2016.
- Date d'édition : 21/08/2016
- DOI : http://dx.doi.org/10.18462/iir.gl.2016.1021
Liens
Voir d'autres communications du même compte rendu (140)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Conditionnement d'air pour le confort;
Hydrocarbures - Mots-clés : Système split; Sécurité; R290; R22; Performance; Conditionnement d'air; Charge en frigorigène
-
Comparison of two reverse-cycle defrosting meth...
- Auteurs : DU Y. J., WU J. H., WANG C., LEI B. W.
- Date : 09/2021
- Langues : Anglais
- Source : 12th International Conference on Compressors and their Systems
- Formats : PDF
Voir la fiche
-
Research of R290 compressor effect on RAC syste...
- Auteurs : GAO B., CHEN Z., GAO Q.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 21st International Compressor Engineering Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Air-air split AC with minimum charge of propane.
- Auteurs : ANDERSON K., LUNDAHL G., GRANRYD E.
- Date : 13/06/2022
- Langues : Anglais
- Source : 15th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2022). Proceedings. Trondheim, Norway, June 13-15th 2022.
- Formats : PDF
Voir la fiche
-
The application and risk assessment of R290 in ...
- Auteurs : HE G., SUN W., TANG W., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Assessment of factors affecting R290 concentrat...
- Auteurs : COLBOURNE D., SUEN K. O.
- Date : 18/06/2018
- Langues : Anglais
- Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Formats : PDF
Voir la fiche