Variable vortex diffuser control without additional energy.
Regulacija varijabilnog vrtloznog difuzora bez pomoci dodatne energije./ Variable vortex diffuser control without additional energy.
Author(s) : ZGAVEC D.
Summary
Up to date and functional equipment for the affordable price is the objective of all air conditioning system investments. The new type of regulation, developed in IMP Klima for the variable diffuser, meets this objective. Regulation is based on the well-known thermostatic head principle. Thermostatic head piston movement is stepless transmitted into the angle of diffuser blades. The mechanism allows automatic angle adjustment between 30 and 75° in temperature range between 20 and 30°C. The whole range is not suitable for all ventilation modes, therefore double regulation in added to the mechanism. First regulation for the cooling mode allows limitation of the initial angle. Second regulation for the heating mode allows limitation of the final angle. The advantage of the new regulation system is automatic adaptation of the blade angle to the inlet air temperature without the need for additional power supply, which eliminates the need for an additional installation.
Details
- Original title: Regulacija varijabilnog vrtloznog difuzora bez pomoci dodatne energije./ Variable vortex diffuser control without additional energy.
- Record ID : 2007-0297
- Languages: Serbian
- Source: Zbornik radova pisanih za 36. kongres o klimatizaciji, grejanju, hladenju + CD-ROM./ Proceedings of the 36th International HVAC&R congress + CD-ROM.
- Publication date: 2005/11/02
Links
See other articles from the proceedings (19)
See the conference proceedings
Indexing
- Themes: Other air-conditioning equipment
- Keywords: Fan; Design; Control (automatic); Air diffuser; Flow rate; Air conditioning
-
Supply fan control methods for VAV systems usin...
- Author(s) : LIU G., LIU M.
- Date : 2008/01/19
- Languages : English
- Source: ASHRAE Transactions. 2008 Winter Meeting, New York City, NY. Volume 114, part 1 + CD-ROM.
View record
-
Detailed measurements of airflow characteristic...
- Author(s) : CHUAH Y. K., HU S. C., BARBER J. M.
- Date : 2000/07/09
- Languages : English
- Source: Air distribution in rooms: ventilation for health and sustainable environment. Roomvent 2000. Proceedings of the 7th international conference.
View record
-
A performance evaluation of the HVAC-based nozz...
- Author(s) : KHAN I. M.
- Date : 2006/05/21
- Languages : English
- Source: ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
View record
-
Damper authority estimation and adaptive flow c...
- Author(s) : FEDERSPIEL C. C.
- Date : 1997/08
- Languages : English
- Source: CLIMA 2000, Brussels 1997, August 30 to September 2, Congress Palace.
View record
-
Development of pressurization airflow design cr...
- Author(s) : SUN W.
- Date : 2003
- Languages : English
- Source: ASHRAE Transactions. 2003 Winter Meeting, Chicago, Illinois. Volume 109, part 1 + CD-ROM.
View record