Document IIF

Simulation de l'écoulement du dioxyde de carbone à l'intérieur des tubes capillaires dans un système frigorifique transcritique.

Simulation of the flow of carbon dioxide in capillary tubes in a transcritical refrigeration system.

Auteurs : CAO X. L., YU S. X.

Résumé

In this paper, the flow of carbon dioxide in capillary tubes in a trans-critical cycle has been simulated under different working conditions. The influences of five parameters (inlet pressure, inlet temperature, inner diameter, mass flow rate and evaporation temperature) on length of capillary were obtained. The results show that length of capillary tube needed is nearly proportional to inlet pressure and is approximately inverse proportional to inlet temperature when other parameters are fixed. It is also shown that the influence of evaporation temperature can be omitted, but the change of capillary length is remarkable when inner diameter or mass flow rate is changed.

Documents disponibles

Format PDF

Pages : ICR07-B2-435

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Simulation of the flow of carbon dioxide in capillary tubes in a transcritical refrigeration system.
  • Identifiant de la fiche : 2008-0146
  • Langues : Anglais
  • Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
  • Date d'édition : 21/08/2007

Liens


Voir d'autres communications du même compte rendu (839)
Voir le compte rendu de la conférence