Résumé
With excellent characteristics of good PLR, precise control, higher thermal comfort, flexible terminal unit control, good heat transfer efficiency, etc, VRV systems are growing rapidly in China in commercial market in recent years and even shares about 35% in 2013. It is noted however, most of the research is limited within the refrigeration system itself or no supported by field data. In this paper, one story office building is investigated, its annual energy consumption is 42.2 kWh/m2.a. Another important feature is that energy consumption of VRV system is of little relevance with building area. In order to give an insight into energy consumption of office building, VRV system and chiller & boiler system connecting with that office building are simulated during different operating schedules with software of Energyplus. Simulation results imply that energy consumption of VRV system is always higher than that of chiller & boiler system. When overtime working load increases from 0 to 40%, the energy consumption increase rate of VRV system is lower than that of chiller & boiler system. In this paper, occupant behaviour of energy saving factor a is addressed which used to describe the impact of running schedule and setting temperature to the energy consumption of VRV system. Its upper limit value is considered to be 0.38 via preliminary analysis.
Documents disponibles
Format PDF
Pages : 6 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Simulation and application study of VRV system in office building.
- Identifiant de la fiche : 30016141
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Date d'édition : 16/08/2015
- DOI : http://dx.doi.org/10.18462/iir.icr.2015.0298
Liens
Voir d'autres communications du même compte rendu (657)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Conditionnement d'air pour le confort
- Mots-clés : Débit variable; Bureau; Consommation d'énergie; Immeuble; Simulation; Frigorigène
-
Investigation of VRF System under Cooling Mode ...
- Auteurs : WAN H., CAO T., HWANG Y., BAE H., OH S.
- Date : 31/08/2021
- Langues : Anglais
- Source : 13th IEA Heat Pump Conference 2021: Heat Pumps – Mission for the Green World. Conference proceedings [full papers]
- Formats : PDF
Voir la fiche
-
Numerical investigation on effects of sub-coole...
- Auteurs : OH B., KIM D., JEONG H., PARK Y., CHOI J., MIN B., CHOI G.
- Date : 2022
- Langues : Anglais
- Source : 2022 Purdue Conferences. 19th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Cooling season full and part load performance e...
- Auteurs : IM P., MALHOTRA M., MUNK J., et al.
- Date : 11/07/2016
- Langues : Anglais
- Source : 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Impact of shading devices, ventilation and ligh...
- Auteurs : ALI-TOUDERT F.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Parametric study and energy balances of an offi...
- Auteurs : KATEB T., ZIED GANNAR M.
- Date : 24/03/2016
- Langues : Anglais
- Source : 1st International Refrigeration, Energy and Environment Colloquium. Proceedings: Hammamet, Tunisia, March 24-27, 2016.
- Formats : PDF