A correlation model of thermal entrainment factor for air curtain in a vertical open display cabinet.

Author(s) : YU K. Z., DING G. L., CHEN T. J.

Type of article: Article

Summary

Thermal entrainment factor (TEF) is an important parameter to describe the cold preservation performance of a display cabinet. In order to calculate the TEF of a display cabinet rapidly and accurately, the method of establishing a correlation model based on computational fluid dynamics simulation results is presented and the correlation model of TEF for typical single and double air curtain in a vertical open display cabinet is developed in this paper. The TEF of display cabinet predicted by the correlation model gives a maximum deviation of -9.4% and a mean deviation of -0.1% compared with the published experimental data. In addition, the correlation model can be used to calculate the air curtain return temperature, showing a maximum deviation of 0.9°C and an average deviation of 0.1°C compared with the published experimental data. [Reprinted with permission from Elsevier. Copyright, 2009].

Details

  • Original title: A correlation model of thermal entrainment factor for air curtain in a vertical open display cabinet.
  • Record ID : 2009-2072
  • Languages: English
  • Source: Applied Thermal Engineering - vol. 29 - n. 14-15
  • Publication date: 2009/10
  • DOI: http://dx.doi.org/10.1016/j.applthermaleng.2009.02.016

Links


See other articles in this issue (5)