Document IIF

Analyse énergétique d'un système frigorifique à compression de vapeur utilisant le HC-290 comme frigorigène de remplacement pour le HCFC-22.

Energetic analysis of a vapour compression refrigeration system using HC-290 as an alternative to HCFC-22.

Résumé

The aim of this research is to analyze experimentally a mechanical vapour-compression refrigeration system using the hydrocarbon propane (R290) as an alternative to R22, in order to reach the requirements of the commercial refrigeration market, which demands alternatives to hydrochlorofluorocarbons (HCFCs). The study was made in a small tank commercially used in milk refrigeration and designed to operate with refrigerant HCFC-22. This paper shows the influences of the factors: temperature of the fluid inside the tank (water instead of milk) and temperature of the cooling air at the condenser, on the performance of the vapour compression cycle. The following parameters were determined: evaporating pressure, condensing pressure, compression work, refrigeration capacity per unit mass of refrigerant and coefficient of performance of the cycle. Experimental results showed that HC-290 can be used in systems originally designed to HCFC-22 leading to better energetic performance and less environmental pollution.

Documents disponibles

Format PDF

Pages : 2009-5

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Energetic analysis of a vapour compression refrigeration system using HC-290 as an alternative to HCFC-22.
  • Identifiant de la fiche : 2009-1995
  • Langues : Anglais
  • Source : 3rd Conference on Thermophysical Properties and Transfer Processes of Refrigerants
  • Date d'édition : 23/06/2009

Liens


Voir d'autres communications du même compte rendu (66)
Voir le compte rendu de la conférence