Document IIF
Performance expérimentale d'un système frigorifique en cascade utilisant l'éthane (HC-170) en tant que frigorigène à l'étage basse température.
Experimental performance of a cascade refrigeration system using ethane (HC-170) as a low stage refrigerant.
Auteurs : RAHADIYAN L., KIM Y. G., SHIN Y. S., et al.
Résumé
This paper presents the performance of ethane (HC-170) as an alternative refrigerant in the low stage of a two-stage cascade refrigeration, with R-22 as the high stage refrigerant. The energetic performances as well as operating condition of R-22/HC-170 system are compared to a system that used R-22/HFC-23. As the low stage evaporation pressure ranges from 1.3 to 2.2 bars, the R-22/HC-170 system shows 0.23-0.37 higher COPs. Furthermore, in the same range, evaporation temperature of ethane is about 1 0.5°C lower than HFC-23.
Documents disponibles
Format PDF
Pages : 2006-1
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental performance of a cascade refrigeration system using ethane (HC-170) as a low stage refrigerant.
- Identifiant de la fiche : 2007-0600
- Langues : Anglais
- Source : Innovative Equipment and Systems for Comfort and Food Preservation.
- Date d'édition : 16/02/2006
Liens
Voir d'autres communications du même compte rendu (51)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Systèmes à compression;
HCFC;
HFC;
Hydrocarbures - Mots-clés : Système frigorifique; R23; Comparaison; R22; Système à compression; Performance; Système en cascade; Experimentation; Éthane; Cycle
-
Investigation of R-290/R-170 substituting R-22/...
- Auteurs : XIE Y. B., LIU C. T., LUN L. Y., et al.
- Date : 05/04/2008
- Langues : Anglais
- Source : Cryogenics and refrigeration. Proceedings of ICCR'2008.
Voir la fiche
-
Experimental performance of a cascade refrigera...
- Auteurs : RAHADIYAN L., CHON Y. S., KIM Y. G., et al.
- Date : 21/05/2006
- Langues : Anglais
- Source : ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
Voir la fiche
-
Study on mix flow characteristics in an auto-ca...
- Auteurs : LIU H. S., ZHANG H., LIU Z. J., et al.
- Date : 05/04/2008
- Langues : Anglais
- Source : Cryogenics and refrigeration. Proceedings of ICCR'2008.
Voir la fiche
-
Análisis exergético de un sistema de refrigerac...
- Auteurs : ARINI R. G., PÉCORA A. A. B.
- Date : 10/2010
- Langues : Espagnol
- Source : IIF-IIR/Frío Calor Aire acond. - vol. 38 - n. 429
- Formats : PDF
Voir la fiche
-
Energetic analysis of a vapour compression refr...
- Auteurs : ARINI R. G., PÉCORA A. A. B.
- Date : 23/06/2009
- Langues : Anglais
- Source : 3rd Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Formats : PDF
Voir la fiche