Document IIF
Comparaison de l'intensité énergétique totale des systèmes de conditionnement d'air conventionnels et des systèmes de conditionnement d'air transcritiques centraux au CO2.
Comparison of total energy intensity of conventional central AC systems with transcritical CO2 AC systems.
Auteurs : VISSER K.
Résumé
The revival of CO2/NH3 cascade technology has seen explosive growth with many successful applications. It was mainly driven by Occupational and Public Health and Safety (OPHS) issues more recently, we have seen the development of transcritical CO2 applications for Mobile Air Conditioning (MAC), supermarket refrigeration, domestic hot water heat pumps, Coca-Cola drink coolers, etc. The European Commission's Environment Directorate has issued the EU F-gases Regulation and MAC directive. There are therefore three significant forces at play. One force is against the more widespread use of NH3. Another force is against HFCs. The third force favours maintaining the existing status quo. In this paper, the advantages and disadvantages of transcritical CO2 systems are compared with conventional industrial NH3 and HFC air-conditioning systems in terms of OPHS, water consumption for cooling, total system COP taking into account all parasitic electrical and refrigeration loads like condenser and cooling tower fans and pumps, air cooled gas coolers, tap-, heating- and AC reheat water heating by the discharge gases of the transcritical CO2 compressors, liquid refrigerant pumps, supply and return air fans, cooling water pumps, chilled water circulating pumps, etc. Suggestions are made on how to best take advantage of locally prevailing seasonal climatic conditions to arrive at minimum energy and water consumption through a year's running.
Documents disponibles
Format PDF
Pages : 2007-2
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Comparison of total energy intensity of conventional central AC systems with transcritical CO2 AC systems.
- Identifiant de la fiche : 2007-2242
- Langues : Anglais
- Sujet : Alternatives aux HFC
- Source : Ammonia Refrigeration Technology for Today and Tomorrow.
- Date d'édition : 19/04/2007
Liens
Voir d'autres communications du même compte rendu (31)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Autres équipements de conditionnement d'air;
HFC;
Ammoniac;
CO2 - Mots-clés : Système frigorifique; Comparaison; Ammoniac; HFC; Cycle transcritique; COP; Frigorigène; Conditionnement d'air; CO2
-
Theoretical performance evaluation of a carbon ...
- Auteurs : LI D., GROLL E. A.
- Date : 01/08/2004
- Langues : Anglais
- Source : Natural Working Fluids 2004: 6th IIR-Gustav Lorentzen Conference
- Formats : PDF
Voir la fiche
-
Experimental results of transcritical CO2 refri...
- Auteurs : APREA C., ROSSI F. de, MAIORINO A.
- Date : 29/05/2006
- Langues : Anglais
- Source : 7th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2006). Proceedings
- Formats : PDF
Voir la fiche
-
Experimental validation and design study of a t...
- Auteurs : ELBEL S., HRNJAK P.
- Date : 29/05/2006
- Langues : Anglais
- Source : 7th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2006). Proceedings
- Formats : PDF
Voir la fiche
-
Experimental comparison of mobile air condition...
- Auteurs : MCENANEY R. P., BOEWE D. E., YIN J. M., PARK Y. C., BULLARD C. W., HRNJAK P. S.
- Date : 14/07/1998
- Langues : Anglais
- Source : Proceedings of the 1998 Purdue International Refrigeration Conference.
Voir la fiche
-
Simulation of a CO2 transcritical cycle for air...
- Auteurs : KOYAMA S., XUE J., KUWAHARA K., et al.
- Date : 23/06/2009
- Langues : Anglais
- Source : 3rd Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Formats : PDF
Voir la fiche